VU meter LEDs

This meter is a multi-step LED; –40, -30, -20, -10 dB. The accurate level indication allows you to monitor the
output signal level at anytime, and match with back-step equipment.

Input Attenuates

The two input attenuator controls, located at the front panel, adjust gain for their respective amplifier
channels in stereo mode. With attenuate fully clockwise at 0 dB, professional power amplifiers have the
rated power (when the rated input is 1,1V) In bridged mode, only channel A’s attenuate controls the power
level, while channel B’s does not function.

Protection Features

Every amplifier incorporates several circuits to protect themselves and the speakers under virtually any
situation. Dap Audio has attempted to make the amplifier as “foolproof” as possible by making it impervious
to short and open circuits, DC Voltage and overheating.

When a problem occurs, that causes a channel to go into a protection mode, the FAULT for that channel will
glow. DC voltage on the output, excessive subsonic frequencies, or thermal overloads will cause the
channel’s output relay to disconnect the speaker load, until the problem is corrected or the amplifier cools
down.

The internal fan(s) will keep the amplifier operating well within its intended temperature range under all
normal conditions.

When a channel’s heat sink temperature reaches 90 ºC, which may indicate an obstructed air supply,
clogged air filter, etc, the channel will disconnect its load. Normal operation will resume automatically once it
cools to 80 ºC. During this time, the channel’s FAULT LED will light.

Short Circuit

If an output is shorted, the protection circuit will be more sensitive, than in the normal protection situation
and will protect the channel’s output transistors from the current stress. The channel’s FAULT LED will light.
If the short circuit remains, the channel will eventually thermally protect itself by disconnecting the load.

DC Voltage Protection

If an amplifier channel detects DC voltage at its output, its output will immediately open to prevent speaker
damage. The channel’s FAULT LED will light.

Subsonic Frequencies

All amplifiers have a built-in subsonic frequency protection circuit, cornered at 10Hz, for each channel.
An additional feature is a special high frequency protection technology, which enables you to automatically
disconnect speakers, when excessive high frequency energy appears at the output.

Turn-On/Turn-Off-Protection

At power up, the speakers are disconnected. The power supplies charge for about 2-3 seconds and
stabilize, and then the speakers are connected. When power is removed, speaker loop is synchronized with
the turn off signal, therefore no thumps or pops are heard.

Speaker-Protection

All amplifiers automatically protect speakers from DC voltage, subsonic signals and excessive high
frequency signal, but users should be aware of the application limits of their speakers.
Be aware that the amplifiers power does not exceed the speaker’s power capabilities.

Summary of Contents for Vintage DPA-1200

Page 1: ...Digital DPA 1200 ORDERCODE D4180 DPA 2400 ORDERCODE D4181 DPA 3400 ORDERCODE D4182...

Page 2: ...rely on DAP Audio for more excellent audio products We design and manufacture professional sound equipment for the entertainment industry New products are being launched regularly We work hard to keep...

Page 3: ...o Dap Audio Vintage Digital Power Series Product Guide Warning Safety instructions Operating Determinations Description Features Frontside Backside Installation Set Up and Operation Maintenance Troubl...

Page 4: ...ver remove warning or informative labels from the unit Do not open the device and do not modify the device Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch...

Page 5: ...nect mains power supply immediately Have a qualified engineer inspect for safety before operating If the device has been exposed to drastic temperature fluctuation e g after transportation do not swit...

Page 6: ...tt RMS 8 2x 600 Watt RMS 4 2x 1200 Watt RMS 4 2x 1700 Watt RMS 4 Overview Frontside 1 Frontside Channel FAULT CLIP 10dB 20dB 30dB 40dB LEDS 2 Channel A Attenuator 3 Power LED 4 Power Switch Circuit Br...

Page 7: ...gnal at Channel B s input produces an amplified signal at Channel B s output Input Attenuator Whenever possible set attenuates fully clockwise to maintain optimum system headroom The input attenuator...

Page 8: ...clogged air filter etc the channel will disconnect its load Normal operation will resume automatically once it cools to 80 C During this time the channel s FAULT LED will light Short Circuit If an out...

Page 9: ...or supplying electric power Troubleshooting DAP Audio Vintage Digital Power Series This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in s...

Page 10: ...10K unbalanced Signal to Noise Ratio 105dB 105dB 105dB Crosstalk 70dB 70dB 70dB Input Connectors 2 x XLR 2J Jack mounting socket Connectors per channel 2 x speaker Stereo Power Supply 230 V 50 60 Hz...

Page 11: ...2005 DapAudio...

Reviews: