Do not insert objects into air vents. 

 

Do not open this device. Risk: hazardous radiation exposure. 

 

Do not run the output of any amplifier channel, back into another channel’s input. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving your 
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT 
control. 

 

For replacement use fuses of same type and rating only. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

In system setup, the amplifier's output power must be 50%-100% more than the loaded loudspeakers 
rated power. 

 

Keep this user’s manual for future consultation. Also remember that the crossover will get a better 
price on the secondhand market if (as well as being in good condition) it has its original 
documentation and packaging. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure that there is sufficient room on all sides of the system for air circulation. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

Prevent distortion! Make sure that all components connected to the DRX-Series have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their limits. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

The best way (even if not always feasible) to avoid ground loops is to connect the electric ground of 
all the equipment to a single central point (“star” system). In this case, the central point can be the 
mixer. 

 

To avoid or solve hum and buzzing troubles, try different combinations of lifting grounds on units that 
are supplied with ground lift switches or make sure all chassis are connected to earth ground, either 
through the A.C. power cord ground or by the front panel rack mount screws. 

 

To emphasize a frequency range, you don’t necessarily have to move its respective sliding control 
upward; try lowering surrounding frequency ranges instead. This way, you avoid causing the next 
piece of equipment in your sound path to overdrive. You also preserve valuable dynamic reserve 
(“headroom”) 

 

WARRANTY: Till one year after date of purchase. 

 

When connecting the other parts of your sound system, watch out for the so-called “ground loops”. 

 

 

 

Summary of Contents for SPLASH 8

Page 1: ...3494 D3595 D3592 D3593 Productname Splash 8A Splash 10A Splash 12A Splash 15A Splash 8 Splash 10 Splash 12 Splash 15 Splash Series Active Passive Highlite International B V Vestastraat 2 6468 EX Kerkr...

Page 2: ...s 5 Panel Description Splash 8A 10A12A 15A 6 Panel Description Splash 8 10 12 15 7 Connection Example 8A 10A 12A 15A 8 Connection Example 8 10 12 15 9 Floor monitor setup 10 Connection Cables 11 Techn...

Page 3: ...t accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the system Always disconnect power from the mains when system is not used O...

Page 4: ...use the wrong kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cab...

Page 5: ...on proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your...

Page 6: ...portation and a pole mount The special shaped side and the excellent gain before feedback makes it also possible to use the Splash series as a stage monitor speaker These properties make this series s...

Page 7: ...ne MIC input on combo connector Input sensitivity switch for Line or MIC Link out Main Volume control Clip indicator Power indicator Countour on off Contour ON preset is to equalize the mix for optima...

Page 8: ...D3595 Panel Description Splash 8 10 12 15 INPUT Receive the power coming from an external power amplifier SPK 1 1 connected 2 2 not connected THRU Direct LINK for connecting in parallel a second speak...

Page 9: ...8 Splash Series Active Passive Ordercode D3588 D3595 Connection Example 8A 10A 12A 15A...

Page 10: ...9 Splash Series Active Passive Ordercode D3588 D3595 Connection Example 8 10 12 15...

Page 11: ...10 Splash Series Active Passive Ordercode D3588 D3595 Floor monitor setup...

Page 12: ...increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbal...

Page 13: ...feet 1 handle on top Mounting 35mm pole mount Connectors Combo XLR male female link Dimensions H x W x D 420 x 270 x 240 mm Weight 5 53Kg Splash 10A System Bi Amp 2 Way Active Speaker Continuous powe...

Page 14: ...c handles Mounting 35mm pole mount Connectors Combo XLR male female link Dimensions H x W x D 607 x 380 x 337mm Weight 13 75Kg Splash 15A System Bi Amp 2 Way Active Speaker Continuous power Low 150W H...

Page 15: ...l Grill Rubber feet 1 handle Mounting 35mm pole mount Connectors Speakon Dimensions H x W x D 420 x 270 x 240 mm Weight 5 81Kg Splash 10 System Passive 2 Way Full range Speaker Continuous power 120W P...

Page 16: ...ber feet 3 ergonomic handles Mounting 35mm pole mount Connectors Speakon Dimensions H x W x D 607 x 380 x 337mm Weight 11 75Kg Splash 15 System Passive 2 Way Full range Speaker Continuous power 200W P...

Page 17: ...16 Splash Series Active Passive Ordercode D3588 D3595 Frequency Response Diagram Splash 8A Splash 10A Splash 12A Splash 15A...

Page 18: ...17 Splash Series Active Passive Ordercode D3588 D3595 Splash 8A Splash 10A Splash 12A Splash 15A...

Page 19: ...unit operates properly do not carry out following steps 1 If the device does not operate properly unplug the device 2 Check the fuse power from the wall all cables etc 3 If all of the above appears to...