9
Compensation of interference with balanced connections
Maintenance
The
DAP Audio
SoundMate Active 3 MKII requires almost no maintenance. However, you should keep the
unit clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not
immerse in liquid. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power,
and then wipe the audio connections with a damp cloth. Make sure connections are thoroughly dry
before linking equipment or supplying electric power.
Replacing a Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens,
follow the directions below to do
so.
1.
Unplug the unit from electric power source.
2.
Insert a screwdriver into the slot in the fuse cover. Turn the screwdriver to the left, at the same time
gently push a bit (Turn and Push). The fuse will come out.
3.
Remove the broken fuse. If brown or unclear, it is burned out.
4.
Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover.
Be sure to use a fuse of the same type and specification. See the product specification label for
details.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps
below in sequence until a solution is found. Once the unit operates properly, do not carry out following
steps.
1.
If the device does not operate properly, unplug the device.
2.
Check the fuse, power from the wall, all cables, etc.
3.
If all of the above appears to be O.K., plug the unit in again.
4.
If you are unable to determine the cause of the problem, do not open the device, as this may
damage the unit and the warranty will become void.
5.
Return the device to your Dap Audio dealer.
Summary of Contents for Soundmate Active 3 MK-II
Page 1: ...Soundmate Active 3 MK II ORDERCODE D3222...
Page 14: ...2008 DapAudio...