Make sure that the amplifier is turned down, before turning the power on or off. So you can avoid 
supersonic frequencies, which could damage your speakers. 

 

Don't put your equipment next to TV, radio, etc., because of interference or distortion. 

 

If you connect other parts of the system, be careful of ground loops. 

 

The best way to avoid ground loops is connecting the electrical system ground to one central 
point ("star" system). In this case the mixer can act as a central point. 

 

Before changing the ground, always turn off your amplifier. 

 

Please read this manual carefully and keep it for future reference. Remember that the amplifier 
has a better value on the market, if you save the carton and all packing materials. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground.  

 

Connecting amplifier outputs to oscilloscopes or other test equipment, while the amplifier is in 
bridged mode, may damage both the amplifier and test equipment. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full 
output. 

 

In system setup, the amplifier's output power must be 50%-100% more than the loaded 
loudspeakers rated power. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the 
input mode switch. 

 

In typical use, please set the volume at 0dB position. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit 
securely (preferably in the original packing material), and return it to your Dap Audio dealer for 
service. 

 

Allow time to cool down, before cleaning or servicing. 

 

For replacement use fuses of same type and rating only. 

 

Prevent distortion! Make sure that all components connected to the device have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their 
limits. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your system. Leave 
the system switched off until it has reached room temperature. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

OPERATING DETERMINATIONS 

 

If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 
You endanger your own safety and the safety of others! 
 

Improper installation can cause serious damage to people and property !

 

 
 
 
 

Summary of Contents for MPA-440

Page 1: ...MPA 440 ORDERCODE D6120...

Page 2: ...ed You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work h...

Page 3: ...DAP Audio MPA 440 Product Guide Warning Safety instructions Operating Determinations Description Features Overview Front panel Overview Back panel Operation Setup Example Connection Cables Maintenanc...

Page 4: ...ution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Do not insert objects into air vents Do not connect this system to a dimmerpack Do not swi...

Page 5: ...Dap Audio device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Dap Audio dealer for service Allow time to...

Page 6: ...Intelligent cooling fan 19 rack mount type 3U size Frontpanel Fig 1 1 Zone selector Use Z1 Z2 Z3 Z4 to assign a channel to zone1 4 2 Volume Use to adjust the volume level for channel 1 4 to your pref...

Page 7: ...r Line In this position the input accepts balanced or unbalanced line signals Phantom Use only balanced microphones when the switch is in position phantom Otherwise you can damage your MPA 440 20 Comb...

Page 8: ...s the operation voltage before connecting the unit to mains Replace the fuse only with a fuse of same specification T315mA 31 Monitor line out Unbalanced mono line level monitor output 32 Monitor 8 1W...

Page 9: ...e 230VAC 50Hz Asia 220VAC 50Hz 60Hz Australia 240VAC 50Hz South America 120VAC 60Hz or 220VAC 50Hz Japan 100VAC 50Hz NOTE Always turn off and disconnect the amplifier from mains voltage before making...

Page 10: ...puts If using the 25V outputs the 70V outputs or the 100V outputs note that all speakers should be wired in parallel The total power of all speakers summed together should never exceed the total power...

Page 11: ...always to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are in good condition a great number of problems faulty co...

Page 12: ...n the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was...

Page 13: ...Line 60dB Input impedance 20k Balanced Input sensitivity impedance CH1 3 XLR 6 3mm combo socket balanced unbalanced Mic 42dB 38dB 600 Line 26dB 20dB 15k LINE IN stereo RCA jack unbalanced CH4 10dB 50k...

Page 14: ...2008 DapAudio...

Reviews: