Make sure that the amplifier is turned down, before turning the power on or off. So you can avoid 
supersonic frequencies, which could damage your speakers. 

 

Don't put your equipment next to TV, radio, etc., because of interference or distortion. 

 

If you connect other parts of the system, be careful of ground loops. 

 

The best way to avoid ground loops is connecting the electrical system ground to one central 
point ("star" system). In this case the mixer can act as a central point. 

 

Before changing the ground, always turn off your amplifier. 

 

Please read this manual carefully and keep it for future reference. Remember that the amplifier 
has a better value on the market, if you save the carton and all packing materials. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground.  

 

Connecting amplifier outputs to oscilloscopes or other test equipment, while the amplifier is in 
bridged mode, may damage both the amplifier and test equipment. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full 
output. 

 

In system setup, the amplifier's output power must be 50%-100% more than the loaded 
loudspeakers rated power. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the 
input mode switch. 

 

In typical use, please set the volume at 0dB position. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit 
securely (preferably in the original packing material), and return it to your Dap Audio dealer for 
service. 

 

Allow time to cool down, before cleaning or servicing. 

 

For replacement use fuses of same type and rating only. 

 

Prevent distortion! Make sure that all components connected to the device have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their 
limits. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your system. Leave 
the system switched off until it has reached room temperature. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

OPERATING DETERMINATIONS 

 

If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 
You endanger your own safety and the safety of others! 
 

Improper installation can cause serious damage to people and property !

 

 
 
 
 

Summary of Contents for MPA-4150

Page 1: ...MPA 4150 ORDERCODE D6121...

Page 2: ...ed You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work h...

Page 3: ...udio MPA 4150 Product Guide Warning Safety instructions Operating Determinations Description Features Overview Front panel Overview Back panel Operation Connection Cables Maintenance Troubleshooting P...

Page 4: ...ution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Do not insert objects into air vents Do not connect this system to a dimmerpack Do not swi...

Page 5: ...Dap Audio device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Dap Audio dealer for service Allow time to...

Page 6: ...Use to adjust the siren level 4 Treble Use to adjust the treble frequencies for each channel to your preference 5 Master Use to adjust the volume level for each channel to your preference 6 Bass Use t...

Page 7: ...D lights up when the output is above 200mV 17 Ready LED The LED lights up when the unit is ready for use Backpanel Fig 2 18 Power amp in Mono RCA in Use this input if You don t want to use the build i...

Page 8: ...pressed a chime signal will be put out 32 Siren remote terminal Use this terminal for connecting a remote switch or relay contact Closing the switch will activate the siren independent of the siren f...

Page 9: ...ution have the attenuators turned down during power up Dip switch settings The MPA4150 has 4 balanced combo inputs You can use these for connecting either jack or XLR cables Each input can be customiz...

Page 10: ...is to avoid overloading the amplifier The total speaker power should be at least the power of the amplifier to avoid damage to the speakers High impedance outputs If using either the 25V the 70V outpu...

Page 11: ...s to your advantage Periodically check that your cables are in good condition that they are correctly wired and that all their contacts are in good condition a great number of problems faulty contacts...

Page 12: ...t in the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse w...

Page 13: ...e 10dB at 10kHz Bass 10dB 100Hz Total harmonic distortion 0 5 1KHz nominal power capacity Signal noise ratio Mic 60dB Line 70dB Tel 60dB Priority for MIC 1 Sensitivity 30dB 5 Outputs for speakers 4 8...

Page 14: ...12 Appendix 1 Block diagram MPA 4150 Fig 9...

Page 15: ...2008 DapAudio...

Reviews: