background image

 

 

Please read this manual carefully and keep it for future reference. Remember that the amplifier 
has a better value on the market, if you save the carton and all packing materials. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground.  

 

Connecting amplifier outputs to oscilloscopes or other test equipment, while the amplifier is in 
bridged mode, may damage both the amplifier and test equipment. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full 
output. 

 

In system setup, the amplifier's output power must be 50%-100% more than the loaded 
loudspeakers rated power. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the 
input mode switch. 

 

In typical use, please set the volume at 0dB position. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit 
securely (preferably in the original packing material), and return it to your Dap Audio dealer for 
service. 

 

Allow time to cool down, before cleaning or servicing. 

 

For replacement use fuses of same type and rating only. 

 

Prevent distortion! Make sure that all components connected to the device have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their 
limits. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your system. Leave 
the system switched off until it has reached room temperature. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

OPERATING DETERMINATIONS 

If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  Any other operation may lead to dangers like short-circuit, 

burns, electric shock, etc. You endanger your own safety and the safety of others! 

 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
Make sure that the device is always connected 

properly

 to the earth!  

 
Improper installation can cause serious damage to people and property!

 

 
 

 

 

Summary of Contents for IPS-SM

Page 1: ...IPS SM ORDERCODE D6508...

Page 2: ...d You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work ha...

Page 3: ...Warning Safety instructions Operating determinations Connecting to the mains Description Features Overview Front panel Overview Back panel Operation Audio Signal Input connection Audio Signal Output...

Page 4: ...duce the system s life Do not open the device and do not modify the device Do not open this device Risk hazardous radiation exposure Only use system indoor avoid contact with water or other liquids Av...

Page 5: ...ause the components are operated at their limits Avoid ground loops Always be sure to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is...

Page 6: ...o channel is selected 4 Output Channels level indicators Below each input indicator is a channel output level meter The LED on bottom indicates that the channel is active 5 Up key Pressing this button...

Page 7: ...ate ground connection Can be useful in case of grounding problems 16 Alarm input 17 Output Channel 1 8 18 Alarm In Socket All incoming alarm signals have to be connected to the 26 pin socket Pin 1 8 a...

Page 8: ...Check that all foam and plastic padding is removed Secure the equipment into a 19 rack Connect all cables Connecting the device Below an example of a possible setup NOTE Always turn off and disconnect...

Page 9: ...these inputs to connect the output of your audio device e g CD player Tuner mixer etc to the desired input channel Fig 4 Audio Signal Output connection Use these outputs to connect your IPS SM to an e...

Page 10: ...nto a slot in the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the o...

Page 11: ...Mic input 13dBV Output level Same as input level Frequency response 20Hz 20kHz Logic level High 5 24V Low 0V short circuit to ground Weight 7 5kg Dimensions 483 x 88 x 370mm Design and product specif...