Description of the device 

 

Features 

 

 

DC 24V function 

 

AM/ FM band 

 

Micro computer chip control, digital tuning system 

 

Touch button control 

 

LCD display 

 

20 radio-station memory function 

 

Manual storage & automatic search function 

 

Level indicator & data memory function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front panel 

 

 

  

 
 
 
 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

             

 Fig. 1 

 

 

1.

 

Up button. 

Used for manual tuning up (FM: 50kHz/ step, AM: 9kHz/ step). 

2.

 

Auto button

.

 

        Used for auto searching and auto saving 20 presets for the selected band. 

3.

 

Band button

Use this button to toggle between the AM or the FM band. 

4.

 

AC LED 

  Indicates that AC power is connected and the device is turned on. The LED will dim if the mains  
  power fails. 

5.

 

DC LED. 

        Indicates that an external 24Vdc power supply is present. 

6.

 

Down button

.

  

Used for manual tuning down(FM: 50kHz/ step, AM: 9kHz/ step).

 

7.

 

Mono button

.

 

Use this switch to toggle between stereo or mono mode. Select mono mode when you are receiving 
a mono broadcast. 

8.

 

Memo button. 

Used for storing a station into memory. 

9.

 

Display 

10.

 

M1 – +10 preset keys 

M1 – +10 buttons can be used to select preset 1 - 20 for each band. 

11.

 

AC Power Switch. 

       This is the main Power switch. Press to turn the amplifier on. 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IPS-PT

Page 1: ...IPS PT ORDERCODE D6513 ...

Page 2: ...ed You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied You can get some of the best quality best priced products on the market from DAP Audio So next time turn to DAP Audio for more great audio equipment Always get t...

Page 3: ...ructions Operating Determinations Connecting to the mains Description Features Overview Front panel Overview Back panel Operation Connecting the device Selecting a station Storing a station in memory Mono stereo switching Remote data link Maintenance Troubleshooting Product Specifications ...

Page 4: ...educe the system s life Do not open the device and do not modify the device Do not open this device Risk hazardous radiation exposure Only use system indoor avoid contact with water or other liquids Avoid flames and do not put close to flammable liquids or gases Always disconnect power from the mains when system is not used Only handle the power cord by the plug Never pull out the plug by tugging ...

Page 5: ...use the components are operated at their limits Avoid ground loops Always be sure to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is dropped or struck disconnect mains power supply immediately Have a qualified engineer inspect for safety before operating If the system has been exposed to drastic temperature fluctuation e g after tr...

Page 6: ...s button to toggle between the AM or the FM band 4 AC LED Indicates that AC power is connected and the device is turned on The LED will dim if the mains power fails 5 DC LED Indicates that an external 24Vdc power supply is present 6 Down button Used for manual tuning down FM 50kHz step AM 9kHz step 7 Mono button Use this switch to toggle between stereo or mono mode Select mono mode when you are re...

Page 7: ...to mains Replace the fuse only with a fuse of same specification T500mA 13 DC 24V Input Used to connect an external back up power supply of 24Vdc e g Battery 14 GND Screw This screw offers a separate ground connection Can be useful in case of grounding problems 15 Remote Data Link Ports Used to Link the remote to another device 16 Remote Data In Port Used to control this device remotely from a Wee...

Page 8: ...and is the same as printed on the rear of the amplifier Damage caused by connecting the amplifier to improper AC voltage is not covered by any warranty Unless otherwise specified when ordered DAP audio amplifiers shipped to customers are configured as follows North America 120VAC 60Hz Europe 230VAC 50Hz Asia 220VAC 50Hz 60Hz Australia 240VAC 50Hz South America 120VAC 60Hz or 220VAC 50Hz Japan 100V...

Page 9: ...tations received will automatically be saved in preset M1 M20 The search will stop as either the band has been searched completely or all presets are full When the auto search is completed preset M20 will be selected Store manually Press the MEMO button In the display the symbols MEM and CH__ will start blinking Now use button M1 10 to store the preset in the desired memory location Mono Stereo sw...

Page 10: ...o a slot in the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product specification label for details Troubleshooting DAP Audio IPS PT This troubleshooting guide i...

Page 11: ...BμV S N ratio 30dB AM 23dBμV S N ratio 20dB S N FM Mono 76dB Stereo 70dB 100dBμV input AM 40dB 80dBμV input Freq Step FM 50kHz AM 9kHz MF FM 10 7MHz AM 450kHz Output Level 330mVrms Protection AC fuse T500mA Weight 7 5kg 16 53lb Dimension LxWxD 485mm x 378mm x 88mm 19 09 x 14 8 x 3 46 Design and product specifications are subject to change without prior notice ...

Page 12: ...2008 DapAudio ...

Reviews: