DAPAudio D6612 Manual Download Page 5

 

Ordercode: D6612 

SCS-230 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 

without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 

Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 

return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 

customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 

product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 

 

Note: If you are given an RMA number, please include the following information on a piece of paper 

inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-

comings and/or visible defects, or perform this check after our announcement that the goods are at their 

disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. 

It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 

damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 

of the delivery.  

Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 

a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 

otherwise agreed in writing. 

Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 

invoice. After this period complaints will not be handled anymore. 

Complaints will only then be considered if the client has so far complied with all parts of the agreement, 

regardless of the agreement of which the obligation is resulting. 

 

 

  

 

 

   

 

Summary of Contents for D6612

Page 1: ...SCS 230 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D6612 MANUAL ENGLISH ...

Page 2: ... 2 Safety Instructions 2 Operating Determinations 3 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Installation 6 Set Up and Operation 6 100V Mode 6 Conventional Amplifier Mode 6 Troubleshooting 6 Product Specification 7 Notes 8 1 ...

Page 3: ...ng Your shipment includes DAP Audio SCS 230 2 mounting brackets User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before you initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system ...

Page 4: ...s to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Dap Audio dealer for service Repairs servicing and electric connection must be carried out by a qualified technician Keep this manual for future reference Clean only with dry cloth Take care of your speaker wires they should be free of damage Damaged speaker wires...

Page 5: ...r 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of mercha...

Page 6: ...Features Power taps 7 5 15 30W Line voltage 100V Impedance 6 8 Ω Speaker size 4 x 2 1 x 1 inch Frequency response 180 18 kHz Sensitivity 91 dB Housing Aluminum Color White IP rating IP44 Dimensions 74 x 68 x 400 mm LxWxH Weight 1 7 kg Overview Fig 01 5 ...

Page 7: ... cable bridge between the white and the thin red cable 03 Connect the thin red cable to the main feed cable Troubleshooting No Sound Always check if all the cables and cords are connected Always turn off power to the area before checking the wires to prevent electric shock If everything works properly and there is still no sound revisit the manufacturer s instructions to make sure they were follow...

Page 8: ... Speaker size 4 x 2 1 x 1 inch Frequency response 180 18 kHz Sensitivity 91 dB Housing Aluminum Color White IP rating IP44 Dimensions 74 x 68 x 400 mm LxWxH Weight 1 7 kg Design and product specifications are subject to change without prior notice Website www Dap audio info Email service highlite nl 7 ...

Page 9: ...Ordercode D6612 SCS 230 Notes 8 ...

Page 10: ...Ordercode D6612 SCS 230 9 ...

Page 11: ...Ordercode D6612 SCS 230 10 ...

Page 12: ... 2015 DAP Audio ...