The best way to avoid ground loops is connecting the electrical system ground to one central point 
("star" system). In this case the mixer can act as a central point. 

 

Before changing the ground, always turn off your amplifier. 

 

Please read this manual carefully and keep it for future reference. Remember that the amplifier has a 
better value on the market, if you save the carton and all packing materials. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground.  

 

Connecting amplifier outputs to oscilloscopes or other test equipment, while the amplifier is in 
bridged mode, may damage both the amplifier and test equipment. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output. 

 

In system setup, the amplifier's output power must be 50%-100% more than the loaded loudspeakers 
rated power. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

In typical use, please set the volume at 0dB position. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Dap Audio dealer for service. 

 

Allow time to cool down, before cleaning or servicing. 

 

For replacement use fuses of same type and rating only. 

 

Prevent distortion! Make sure that all components connected to the DSA have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their limits. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the same 
electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

OPERATING DETERMINATIONS 

If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  Any other operation may lead to dangers like short-circuit, 

burns, electric shock, etc. You endanger your own safety and the safety of others! 

 

Connection with the mains 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
Make sure that the device is always connected 

properly

 to the earth!  

 
Improper installation can cause serious damage to people and property!

 

 
 

Summary of Contents for D6503

Page 1: ...IPS AM ORDERCODE D6503...

Page 2: ...d You can rely on DAP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work ha...

Page 3: ...structions Operating Determinations Connecting to the mains Description Features Overview Front panel Overview Back panel Operation Connecting the device Linking more units Using the active up down sw...

Page 4: ...connect this system to a dimmer pack Do not switch the system on and off in short intervals as this would reduce the system s life Do not open the device and do not modify the device Do not open this...

Page 5: ...all components connected to the DSA have sufficient power ratings Otherwise distortion will be generated because the components are operated at their limits Avoid ground loops Always be sure to connec...

Page 6: ...90 SLAVE3 controls CH91 CH120 E g SLAVE 3 LED and CH12 LED light both up This indicates that alarm CH102 is active 3 Alarm Status Display Turn on the power switch alarm LEDs 1 30 light up green which...

Page 7: ...unit will recognize an alarm signal as either a logic 1 high or as a logic 0 low signal A logical 1 signal should range between 5V and 24V Input current draw is less than 3mA 14 Activate DOWN Switch T...

Page 8: ...25 pin sockets are used to output the alarm signals Pin 1 10 are live terminals indicated by LED 11 20 Pin 14 23 are com Pin 11 13 and pin 24 25 are not connected The alarm output sockets will be acti...

Page 9: ...WPT Check that all foam and plastic padding is removed Secure the equipment into a 19 rack Connect all cables Connecting the device Below an example of a possible setup NOTE Always turn off and discon...

Page 10: ...e linked only the OR GATE OUT of the HOST is valid Using The Active Up Active Down Dipswitches Using the active up active down DIP switches allows you to link up to 4 neighbor zones to an alarm channe...

Page 11: ...mple 2 We want to Link 3 alarms up and 4 alarms down to each incoming alarm The DIP switches should be set according the following diagram In case of alarm on channel 14 an alarm will also be sent to...

Page 12: ...oduct will not function whatsoever If this happens follow the directions below to do so 1 Unplug the unit from electric power source 2 Insert a screwdriver into the slot in the fuse cover Open the fus...

Page 13: ...ption Less then 18W Alarm Output Channel 30ch Input Logic Level 5 24V High Level Signal or 0V selectable Alarm Output Level 0V Short Link Up Down 4 Channel Extension Weight 6 73kg 14 84lb Dimension Lx...

Page 14: ...2007 DapAudio...

Reviews: