background image

 

  

 

 

   

 

Pure-10A 10” Full Range Top Cabin 

Order code: D3719 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 

 

Summary of Contents for D3719

Page 1: ...Pure 10A 10 Full Range Top Cabin V1 Order code D3719 MANUAL Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands ENGLISH...

Page 2: ...15AS Pure 18AS 10 Connection Example 2 2 x Pure 10A Pure 12A Pure 15A and 1 x Pure 15AS Pure 18AS 11 Control Panel 12 Main Menu Options 12 1 Preset 13 2 Low EQ 13 3 Mid EQ 13 4 High EQ 13 5 High Pass...

Page 3: ...1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before your initia...

Page 4: ...e and the power cord from time to time Make sure that the signals into the mixer are balanced otherwise hum could be created Make sure that there is sufficient room on all sides of the system for air...

Page 5: ...per installation can cause serious injuries and damage of property The Pure 10A speaker can be placed on a flat stage floor or be hung from a ceiling by means of the Speaker hanging eye D8436 Refer in...

Page 6: ...our phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perf...

Page 7: ...river 19 3 W RMS high driver Speaker low 10 4 50 mm Voice coil Frequency response 6 dB 52 Hz 20 kHz Max SPL 1 m 125 dB Input impedance 10 k Input line 2 Dispersion horn HxV 90 x 60 Cooling Forced cool...

Page 8: ...will send the signal received on input 1 to the connected speaker CH2 The Pure 10A will send the signal received on input 2 to the connected speaker CH1 CH2 The Pure 10A will send the signal received...

Page 9: ...2 Press the button to select the sensitivity of the input 2 Choose between a microphone or a line level device 16 Combo 3 pin XLR 6 3 mm jack connector INPUT 1 Connect a line level device or a microph...

Page 10: ...Pure 10A Check if all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power s...

Page 11: ...e 1 2 x Pure 10A Pure 12A Pure 15A and 2 x Pure 15AS Pure 18AS Make your initial connections with all the equipment powered off and ensure that all the main volume controls are turned completely to th...

Page 12: ...l the main volume controls are turned completely to the minimum Follow the steps below 01 Connect the outputs on your mixer with the inputs on the Pure 15AS Pure 18AS 02 Connect the Link connectors on...

Page 13: ...display will show a splash screen with the Pure Series logo 02 5 seconds later the display will show the start screen LEVEL indicates the master signal level CH1 and CH2 indicate the current input si...

Page 14: ...set the low equalizer The adjustment range is between 12 dB and 6 dB 02 Press the control 19 to confirm 3 Mid EQ In this menu you can set the mid equalizer 01 Turn the control 19 to set the mid equal...

Page 15: ...set the delay The adjustment range is between 0 200 ms The distance will change accordingly 02 Press the control 19 to confirm 7 Limit In this menu you can set the signal threshold 01 Turn the control...

Page 16: ...een 0 20 from dark to brightest 02 Press the control 19 to confirm Never set the contrast to 0 The display will turn so dark that the displayed text will be invisible 11 Display In this menu you can a...

Page 17: ...press the control 19 to insert the new password 04 Press the control 19 to confirm 05 Turn and press the control 19 to repeat confirm the new password 06 Press the control 19 to confirm The device wil...

Page 18: ...umber 01 18 04 Press the control 19 to confirm 05 Turn the control 19 to select a desired symbol for the character 06 Press the control 19 to confirm 07 Repeat steps 3 6 to edit the remaining characte...

Page 19: ...efault settings 02 Press the control 19 to confirm 03 If you have chosen YES you will need to insert the password 04 Turn and press the control 19 to insert the current password 05 Press the control 1...

Page 20: ...life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Headphones Unbalanced...

Page 21: ...re is still no sound revisit the manufacturer s instructions to make sure they were followed during installation If everything was installed correctly and there is still no sound you may want to consi...

Page 22: ...L 1 m 125 dB Input impedance 10 k Input line 2 Dispersion horn HxV 90 x 60 Cooling Forced cooling Audio connector 2 x combo 3 pin XLR 6 3 mm jack IN 3 pin XLR Link 3 5 mm mini jack Aux IN Mains connec...

Page 23: ...22 Pure 10A 10 Full Range Top Cabin Order code D3719...