background image

 

  

 

 

   

 

M10 – M12 – M15 

Ordercode: D3660 – D3661 – D3662  

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output. 

 

Do not open this device. Risk: hazardous radiation exposure. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving your 
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT 
control. 

 

For replacement use fuses of same type and rating only. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

Keep this user’s manual for future consultation. Also remember that the crossover will get a better 
price on the secondhand market if (as well as being in good condition) it has its original 
documentation and packaging. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure that there is sufficient room on all sides of the system for air circulation. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

Prevent distortion! Make sure that all components connected to the M10/M12/M15 active monitor 
have sufficient power ratings. Otherwise distortion will be generated because the components are 
operated at their limits. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

The best way (even if not always feasible) to avoid ground loops is to connect the electric ground of 
all the equipment to a single central point (“star” system). In this case, the central point can be the 
mixer. 

 

To avoid or solve hum and buzzing troubles, try different combinations of lifting grounds on units that 
are supplied with ground lift switches or make sure all chassis are connected to earth ground, either 
through the A.C. power cord ground or by the front panel rack mount screws. 

 

To emphasize a frequency range, you don’t necessarily have to move its respective sliding control 
upward; try lowering surrounding frequency ranges instead. This way, you avoid causing the next 
piece of equipment in your sound path to overdrive. You also preserve valuable dynamic reserve 
(“headroom”) 

 

WARRANTY: Till one year after date of purchase. 

 

When connecting the other parts of your sound system, watch out for the so-called “ground loops”. 

 
 

Disposing of this product should not be placed in municipal waste and should be 
separate collection. 

 

 

 

Summary of Contents for D3660

Page 1: ...M10 M12 M15 Active monitor Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3660 D3661 D3662 MANUAL ENGLISH...

Page 2: ...Safety Instructions 2 Connection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Features 5 Optimized soundfield projection 5 Panel Description 6 Connection Cables 6 Connecti...

Page 3: ...le parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized mo...

Page 4: ...ls should be clear Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never remove warning or informative lab...

Page 5: ...oper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your addr...

Page 6: ...act stage monitor Wedge configuration decreases the resonance of the standing wave in the cabinet Using hi density matrix spray paint technology for the cabinets The bottom bracket design makes mounti...

Page 7: ...ume control AC fuse EQ Presets Monitor FOH Main power switch Connection Cables Take care of your cables always holding them by the connectors and avoiding knots and twists when coiling them This gives...

Page 8: ...0 D3661 D3662 For these applications the unit provides 1 4 TRS and XLR connectors to easily interface with most professional audio devices Follow the configuration examples below for your particular c...

Page 9: ...8 M10 M12 M15 Ordercode D3660 D3661 D3662 Frequency Response Diagram M10 M12 M15...

Page 10: ...eutrik Powercon Housing Wedge design 15mm MDF with Scratch Resistant Black Paint Dimensions HxWxD 363 x 351 x 323mm Net Weight 11 4Kg Model M12 System Active Bi Amp 12 Monitor Output Power Class D 335...

Page 11: ...dB Audio Input XLR Jack Combo balanced Link Output XLR male balanced External Controls Mic Line switch EQ Preset switch Monitor FOH Ground Lift switch Volume control Signal Limiter indication LED Powe...

Page 12: ...2013 DAP Audio...