DanVex DEH-900i Operation Manual Download Page 2

R

www.danvex.fi

1

Summary of Contents for DEH-900i

Page 1: ...DanVex DEH 900i DanVex DEH 1200i Dehumidifiers Operation manual ...

Page 2: ...R www danvex fi 1 ...

Page 3: ...ification principles Attention These units cannot be used for air cooling Use of DanVex dehumidifier Despite of windows and doors insulation quality damp and moisture can penetrate even through thick concrete walls It can take 1 2 months for the water used for construction concrete works whitewashing plasterworks etc to dry out The moisture that has penetrated masonry following high water or flood...

Page 4: ...outside 2 By the air dehumidification The moist air in an enclosed room is continuously dehumidified by the condensation principle or by other dehumidification method In terms of energy consumption the air dehumidification has one essential advantage the energy expenditure requirements are limited by the air volume in the existing room only The heat generated during the air dehumidification proces...

Page 5: ...oled the maximum water vapor volume that can be absorbed continuously reduces the water vapor volume contained in the air remains however the same and the relative humidity increases If the air temperature falling continues the capacity to absorb the water vapor volume is continuously reduced until the air becomes saturated which is equal to the maximum water vapor content in the air This temperat...

Page 6: ... dehumidifier The air flow is cooled on the way through the evaporator condenser system till its temperature is below the dew point Water vapor condenses it is collected in a condensate trap inside the unit The collected moisture is discharged in the form of water 5 Heat of condensation The energy transferred from the condenser to the air consists of The heat earlier transferred from the evaporato...

Page 7: ...es or in case the unit is not used for the intended purpose The following safety instructions must be observed It is prohibited to install or operate the units in the locations subject to explosion hazard It is prohibited to install or operate the units in the locations with oil sulphur chlorine or salt containing atmospheres The units must be installed upright It is prohibited to use a direct jet...

Page 8: ...ssure fail safe and long term operation of the unit The unit complies with the fundamental safety and health requirements of the existing EU regulations The unit is easy and safe to operate Dehumidifier operation The fan intakes moist air through air intake grill located at the front of the dehumidifier equipped with an air filter Than the air flows through evaporator and condenser located in the ...

Page 9: ... to the waste water disposal system should be connected with the connector external part In this case the humidifier can work continuously without interruptions caused by the condensate discharge from the filled tank Unit location The unit is operated in the buildings where dry air is necessary for technological processes people comfort and where it prevents significant financial losses due to goo...

Page 10: ... 0100 Part 704 for electric current supply sources equipped with automatic circuit breakers If the unit is installed in humid premises such as laundries or cellars it should be equipped with proper automatic circuit breakers at the buyer s expense Dehumidifier design models DanVex DEH 900i and DEH 1200i 9 Electric cable Humidity sensor Transportation handle Cover Hose Condensate tank ...

Page 11: ...R www danvex fi 10 Grill Air filter Control panel Connector ...

Page 12: ...creen and click or to adjust the time B In working mode press timer to set Auto stop time off time will flash in screen and click or to adjust the time 3 button Press this button directly to increase the set humidity Buzzer buzzes once for each pressing and the set humidity decreases by 1 RH Successive operation can be achieved by pressing this button successively Press Time button before pressing...

Page 13: ... time Press the Time button for the first time the hour time on the display flashes press and to adjust the current hour and minute time Press the Time button for the second time the Start up time on the LCD flashes press and to adjust the current hour and minute time Press the Time button for the third time the Stop time on the LCD flashes Press and to adjust the current hour and time Press the T...

Page 14: ...tore the current status before the power is cut and enter the operation mode before power cut automatically after power is supplied 5 Range for humidity is 20 90 6 If the dehumidifier is going to be spared for a long time please unload the power cord or cut the power 7 Auto detection of temperature humidity failure a When the system detects that temperature sensor exceeds the limited range the sys...

Page 15: ...hat temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock accidents Please place the machine in firm places If the machine falls down the water in water tank may leak out and damages stuff around and results in creepage and cause fire or electric shock accident...

Page 16: ...own the front panel clear the filter mesh Tap the filter mesh slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water 40 and add appropriate neutral scour and brush and then wash with clear water and dry it Direct sunlight or baking shall be avoided to prevent deformation Failure Cause analysis Method Dehumidifier cannot work 1 Power cut 2 Power switch is not energized 3 P...

Page 17: ...acity Internal condensate tank capacity Cooling agent Power Frequency Rated consumption Sound pressure Depth Width Height Gross weight С RH l day m3 hour liters V Hz kW dB A mm mm mm kg DEH 1200i 5 32 40 95 120 1150 14 R407c R22 230 50 1 86 64 514 633 940 57 DEH 900i 5 32 40 95 90 1000 14 R407c R22 230 50 1 47 64 514 633 940 52 Specifications ...

Page 18: ...R www danvex fi Attachment Electrical diagram 17 ...

Page 19: ...e equipment normal operation All recommendations and instructions of the manufacturer concerning the equipment installation operation and maintenance were observed Only original parts and materials were used for the equipment maintenance and repair R www danvex fi 18 1 Where the above troubles cannot be fixed and repair is needed please contact supplieror distributor Do not disassemble without aut...

Page 20: ......

Reviews: