See the chapter «Maintenance and service». 

Important information on electrical connections 

The unit connection to the power supply should be done in accordance with  DIN VDE 0100, 
Part 704 for electric current supply sources equipped with automatic circuit-breakers. 
If the unit is installed in humid premises such as laundries or cellars it should be equipped 
with proper automatic circuit-breakers at the buyer's expense. 

Dehumidifier design (models 

DanVex DEH-900i 

and

 DEH-1200i)

9

Electric cable  

Humidity sensor  

Transportation handle  

Cover  

Hose  

Condensate tank  

Summary of Contents for DEH-1200i

Page 1: ...DanVex DEH 900i DanVex DEH 1200i Dehumidifiers Operation manual...

Page 2: ...R www danvex fi 1...

Page 3: ...fication principles Attention These units cannot be used for air cooling Use of DanVex dehumidifier Despite of windows and doors insulation quality damp and moisture can penetrate even through thick c...

Page 4: ...utside 2 By the air dehumidification The moist air in an enclosed room is continuously dehumidified by the condensation principle or by other dehumidification method In terms of energy consumption the...

Page 5: ...led the maximum water vapor volume that can be absorbed continuously reduces the water vapor volume contained in the air remains however the same and the relative humidity increases If the air tempera...

Page 6: ...dehumidifier The air flow is cooled on the way through the evaporator condenser system till its temperature is below the dew point Water vapor condenses it is collected in a condensate trap inside the...

Page 7: ...s or in case the unit is not used for the intended purpose The following safety instructions must be observed It is prohibited to install or operate the units in the locations subject to explosion haz...

Page 8: ...sure fail safe and long term operation of the unit The unit complies with the fundamental safety and health requirements of the existing EU regulations The unit is easy and safe to operate Dehumidifie...

Page 9: ...to the waste water disposal system should be connected with the connector external part In this case the humidifier can work continuously without interruptions caused by the condensate discharge from...

Page 10: ...0100 Part 704 for electric current supply sources equipped with automatic circuit breakers If the unit is installed in humid premises such as laundries or cellars it should be equipped with proper aut...

Page 11: ...R www danvex fi 10 Grill Air filter Control panel Connector...

Page 12: ...reen and click or to adjust the time B In working mode press timer to set Auto stop time off time will flash in screen and click or to adjust the time 3 button Press this button directly to increase t...

Page 13: ...time Press the Time button for the first time the hour time on the display flashes press and to adjust the current hour and minute time Press the Time button for the second time the Start up time on t...

Page 14: ...ore the current status before the power is cut and enter the operation mode before power cut automatically after power is supplied 5 Range for humidity is 20 90 6 If the dehumidifier is going to be sp...

Page 15: ...at temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock acci...

Page 16: ...wn the front panel clear the filter mesh Tap the filter mesh slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water 40 and add appropriate neutral scour and brush and then wa...

Page 17: ...city Internal condensate tank capacity Cooling agent Power Frequency Rated consumption Sound pressure Depth Width Height Gross weight RH l day m3 hour liters V Hz kW dB A mm mm mm kg DEH 1200i 5 32 40...

Page 18: ...R www danvex fi Attachment Electrical diagram 17...

Page 19: ...equipment normal operation All recommendations and instructions of the manufacturer concerning the equipment installation operation and maintenance were observed Only original parts and materials wer...

Page 20: ......