background image

 

0

8

7

4

0

3

 •

 Ve

rs

io

1

.1

 •

 0

1

.0

6

.2

0

1

5

 

 
 

 

TKS 60 

Service manual 
Rev. 1.1 
en - se 

 

Summary of Contents for TKS 60

Page 1: ...1 087403 Version 1 1 01 06 2015 TKS 60 Service manual Rev 1 1 en se...

Page 2: ...New District Jiangsu 215219 Suzhou China Phone 86 512 6667 8500 Fax 86 512 6667 8500 dantherm cn dantherm com www dantherm air handling com cn Dantherm Limited 12 Windmill Business Park Windmill Road...

Page 3: ...ion 1 General information 2 TKS models 4 Technical data TKS 60 5 Dimensions 6 Mount filter 7 Installation 9 Flow chart 12 Electrical diagram 48 V DC ACUE 3000 13 Electrical diagram 230 V AC TKS 3000A...

Page 4: ...compliant with the following directives 2006 42 EC Machinery Directive 2006 95 EC Low Voltage Directive including 93 68 EEC where is a requirement 2004 108 EC EMC Directive 2004 65 EC RoHS Directive 2...

Page 5: ...1 1 01 06 2015 TKS models Overview This is an overview of the various TKS installation alternatives TKS 60 Indoor floor Indoor wall outdoor option Air flow Indoor floor Indoor wall outdoor option Con...

Page 6: ...position of the controller Step Action 1 Loosen and remove screws in each corner of the front panel 2 Remove front panel 3 Loosen and remove screws in each corner of the casing 4 Twist the casing 180...

Page 7: ...Specification Cover Value Weight Estimated max 60 kg Constituent plate compo nents Zinc aluminium AZ150 0 9 2 0 mm Frame Aluminium 1 5 mm minimum thickness External sandwich panels Painted galvanised...

Page 8: ...ram below shows the dimensions of the free cooling unit TKS 60 Handle This unit has been equipped with one handle that can be secured using a padlock In order to open the unit the handle must first be...

Page 9: ...7 087403 Version 1 1 01 06 2015 Mount filter 1 2 Fit sealing strips Continued overleaf 35 mm...

Page 10: ...8 Mount filter continued 3 3...

Page 11: ...9 087403 Version 1 1 01 06 2015 Installation Installation Dimen sional diagram wall outdoor outdoor only cable tie Continued overleaf Fit sealing strip...

Page 12: ...10 Installation cont Installation Dimen sional diagram floor Continued overleaf Fit sealing strip...

Page 13: ...11 087403 Version 1 1 01 06 2015 Installation cont Installation Dimen sional diagram wall Indoor Continued overleaf...

Page 14: ...0 The illustration below shows schematically how the air flow enters the electronics cabi net The illustration also shows some accessories and other equipment that can be con nected to the control box...

Page 15: ...13 087403 Version 1 1 01 06 2015 Electrical diagram 48 V DC ACUE 3000...

Page 16: ...14 Electrical diagram 230 V AC TKS 3000A EC...

Page 17: ...out and documented at an interval of a maximum of one year The documentation may take the form of a writ ten log Once you have fin ished Before leaving the electronics cabin make sure that the contro...

Page 18: ...an 230 V Type B R3G 355 RT01 L1 088024 Control unit 48 V ACUE 3000 840012 Control unit 230 V TKS 3000A EC 840014 External temperature cord sensor TC function only SG TD5A 120cm 068421 External tempera...

Page 19: ...talled Check that the heater becomes warm 2 120 Damper to outdoor air opens if installed Check that the damper opens 3 60 Fan signal ramps up to maximum speed Check that the fan ramps up to maximum sp...

Page 20: ...tivity Acknowl edgement Fire smoke alarm Activate the smoke detector Check that everything stops Fan heater AC and that the dampers close The display shows Fire alarm Signature Test report information...

Page 21: ...Introduktion 19 Generell information 20 TKS modeller 21 Tekniska data TKS 60 23 Dimensioner 24 Montera filter 25 Montering 27 Fl desschema 30 Elschema 48V DC ACUE 3000 31 Elschema 230V AC TKS 3000A EC...

Page 22: ...kive intygar h rmed att enheten typ 367007 verensst mmer med f ljande direktiv 2006 42 EG Maskindirektivet 2006 95 EG L gsp nningsdirektivet inklusive 93 68 EEC d r det kr vs 2004 108 EG EMC direktive...

Page 23: ...3 Version 1 1 01 06 2015 TKS modeller versikt Det h r r en versikt ver de olika TKS monteringsalternativer TKS 60 Inomhus golv Inomhus v gg utomhus tillval Luftfl de Inomhus golv Inomhus v gg utomhus...

Page 24: ...tyrcentral Step Action 1 Lossa skruvarna i varje h rn av frontpanelen 2 Skruva loss styrcentralens frontlock 3 Lossa och ta bort skruvarna i varje h rn som h ller styrcentral l dan 4 Vrid styrcentrale...

Page 25: ...Bet ckning V rde Vikt Uppskattat till max 60 kg Ing ende pl tdetaljer Aluzink AZ150 0 9 2 0 mm Ram Aluminium 1 5 mm minimal tjocklek Utsida sandwichpaneler Lackad f rzinkad st lpl t mediumbl f rg RAL...

Page 26: ...tningen nedan visar dimensioner f r frikylningsenheten TKS 60 Handtag Det h r aggregatet har utrustats med et stycken handtag som kan l sas med h ngl s F r att ppna ska man f rst f lla ut handtaget d...

Page 27: ...25 087403 Version 1 1 01 06 2015 Montera filter 1 2 Montera t tlister Continued overleaf 35 mm...

Page 28: ...26 Montera filter continued 3 3...

Page 29: ...27 087403 Version 1 1 01 06 2015 Montering Montering M ttrit ning v g utomhus utomhus endast buntband Forts ttning p n sta sida Montera t tlist...

Page 30: ...28 Montering forts ttning Montering M ttrit ning golv Forts ttning p n sta sida Montera t tlist...

Page 31: ...29 087403 Version 1 1 01 06 2015 Montering forts ttning Montering M ttrit ning v g Inomhus Continued overleaf...

Page 32: ...desschema TKS 60 Bilden nedan visar schematiskt hur luftfl det g r inne i elektronikboden I samma bild visas n gra tillbeh r och vrig utrustning som kan kopplas till styrcentralen Forts ttning p n sta...

Page 33: ...31 087403 Version 1 1 01 06 2015 Elschema 48V DC ACUE 3000...

Page 34: ...32 Elschema 230V AC TKS 3000A EC...

Page 35: ...maximalt 1 r Dokumentationen kan vara i form av en skriftlig logg N r du r klar Innan du l mnar elektronikboden se till att kontrollenheten r fri fr n larm Rekommenderad serviceordning Det rekommender...

Page 36: ...H1 088021 Fl kt 230V Typ B R3G 355 RT01 L1 088024 Styrenhet 48V ACUE 3000 840012 Styrenhet 230V TKS 3000A EC 840014 Sladdgivare f r utetemperatur endast vid TC funktion SG TD5A 120cm 068421 Utetemper...

Page 37: ...ir varm 2 120 Spj ll mot uteluft ppnas om installerat Kontrollera att spj ll ppnas 3 60 Fl ktsignal rampas upp till maximalt varvtal Kontrollera att fl kten rampart upp till maximal hastighet 4 120 TC...

Page 38: ...g Fire smoke alarm Aktivera r kdetektorn Kontrollera att allting stoppas Fl kt v rmare AC och att spj llen st ngs Displayen visar Brand larm Underskrift Testrapportinformation Site stationsbeteckning...

Page 39: ...21 130 40 Fax 0 121 133 70 infose dantherm com www dantherm se Dantherm Air Handling Suzhou Ltd Bldg 9 No 855 Zhu Jiang Rd Suzhou New District Jiangsu 215219 Suzhou China Phone 86 512 6667 8500 Fax 86...

Page 40: ...38 Dantherm Air Handling A S Marienlystvej 65 7800 Skive Denmark www dantherm com service dantherm com 087403 087403...

Reviews: