background image

en

it

de

es

fr

nl

pt

da

fi

no

sv

pl

ru

cs

hu

sl

tr

hr

lt

lv

et

ro

sk

bg

uk

bs

el

zh

INDEX

1... INTRODUCTION
2... GENERAL DESCRIPTION OF THE UNIT
3... PRELIMINARY OPERATIONS
4... START-UP
5... MAINTENANCE
6... ALARM LIST

►►►1. INTRODUCTION

►►1.1. INTRODUCTION

The manual is intended for the end user only

in regard to operations that can be performed

with closed panels. The operations that re-

quire to open doors or panels with tools must

only be performed by expert personnel. Each

appliance must be connected to the power

supply via a cable with a power plug supplied

with the unit. For maintenance operations, the

power plug must always be disconnected to

allow the operator to intervene in safe condi-

tions.

If assistance or spare parts are required, read

the identification plate located outside of the

unit to identify the appliance (model and serial

number).

►►1.2. GENERAL SAFETY RULES

The purpose of the manual and of the entire

documentation supplied is to allow both the

installer and operator to correctly perform the

installation, start-up and maintenance of the

equipment, without causing damage to the

personnel in charge and to the unit.

Each appliance is subject to a risk assessment

carried out in compliance with current legisla-

tion, which defines the necessary actions and

implements the protective measures required

to achieve the risk reduction objectives.

All activities regarding the operation and main-

tenance of the unit must be performed:

Only by properly trained people, who must

implement safe working practices and use

the personal protective equipment appropri-

ate to the specific task performed, based on

their specific qualification.

Only by properly trained people who have

read and fully understood the manuals,

technical documents and safety documents.

Use of the appliance must not be allowed to

anyone who is not adequately trained and

skilled.

This manual, the technical documents and 

any security documents attached must be 

read and stored for the entire lifespan of the 

appliance:

 

CAUTION: This appliance is designed 

for use in an indoor environment. 

 

CAUTION: The unit must be connected 

to an electrical system that complies with 

local electrical safety regulations.

 

CAUTION: The unit must be placed by 

following  the  dimensions  and  spaces  re

-

quired, including the minimum spaces al

-

lowed by adjacent structures.

 

CAUTION: This equipment must always 

be connected to earth. We decline any li

-

ability for any danger or damage caused if 

this requirement is not complied with.

 

CAUTION:  Sharp  tools  (screwdrivers, 

needles  or  the  like)  must  not  be  inserted 

into  the  grids  or  inside  any  other  panel 

opening, especially when the unit is open 

to remove the filter.

 

CAUTION: All maintenance and clean

-

ing  operations  on  the  unit  must  be  per

-

formed with the power supply disconnect

-

ed. Never remove the front grille or open 

any  part  of  the  unit  without  first  discon

-

necting the plug from the socket.

 

CAUTION:  Do  not  use  water  to  clean 

the unit. Use a wet cloth to clean the unit. 

Summary of Contents for MASTER DH 26

Page 1: ...V hu PRIRO NIK Z NAVODILI ZA UPORABO IN VZDR EVANJE sl KULLANIM VE BAKIM KiTAP I I tr KNJI ICA O UPORABI I ODR AVANJU hr NAUDOJIMO IR PRIE I ROS KNYGEL lt LIETO ANAS UN TEHNISK S APKOPES GR MATI A lv...

Page 2: ...__________________________________________________________ _______________________________________________________________________________ _____________________________________________________________...

Page 3: ...0 W 3 1 A 220 240 V 50 Hz 890 W 4 4 A 220 240 V 50 Hz 1 200 W 6 A 220 240 V 50 Hz 1 250 W 6 A dB A 46 dB 53 dB 53 dB 50 dB 50 dB 8 l 12 l 12 l 12 l 12 l 30 kg 43 kg 47 kg 66 kg 69 kg 2 6 mPa LRA 9 A 2...

Page 4: ...8 8 A dB A 53 dB 53 dB 12 l 12 l 46 kg 50 kg 2 6 mPa LRA 16 A 220 240 V LRA 32 A 110 120 V 2 6 mPa LRA 21 6 A 220 240 V LRA 43 2 A 110 120 V CO2 Eq 1 5 1 4 GWP 4 4 30 C UR 80 30 80 IMPORTANT In order...

Page 5: ...IGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT LI JOONISED IMAGINI OBR ZKY SLIKE 1 DH 26 DH 44 DH 62 DH...

Page 6: ...ICTURES FIGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT LI JOONISED IMAGINI OBR ZKY SLIKE 2 3 6 1 5 4 3...

Page 7: ...ORKING FULL ON OFF HUMIDITY HOURS 0 240V I 110V PICTURES FIGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT...

Page 8: ...6 7 5 PICTURES FIGURE ABBILDUNGEN FIGURAS FIGURES FIGUREN FIGU RAS FIGURER KUVAT FIGURER FIGURER ILUSTRACJE OBR ZKY BR K SLIKE EK LLER SLIKE ILIUSTRACIJOS ATT LI JOONISED IMAGINI OBR ZKY SLIKE...

Page 9: ...operation and main tenance of the unit must be performed Only by properly trained people who must implement safe working practices and use the personal protective equipment appropri ate to the specifi...

Page 10: ...the manufacturer The appliance must be placed in a room that does not have ignition sources con tinuously in operation e g open flames a gas appliance while running or an electric heater running Do no...

Page 11: ...sed collection or recycling centres follow the local regulations in force CAUTION Depending on the model as semble the appliance with any handles wheels and all relevant hardware FIG 3 housed inside t...

Page 12: ...the ON status but in stand by mode i e the compressor is off ALARM LED This LED is on when the unit is in alarm The display will show the error message WORKING LED This LED is on when the compressor...

Page 13: ...LTER FROM THE APPLIANCE TO PERFORM CLEANING IT IS FORBIDDEN TO PERFORM CLEAN ING WITH THE FILTER INSTALLED 5 2 SPARE PARTS Should it be required to replace one or more parts during maintenance by spec...

Page 14: ...temperature too low Room temperature conditions not suit able for operation ALARM Prob Humidity probe malfunc tion In any case the unit continues to function Contact the authorised assistance centre A...

Page 15: ...clare that it is compliant with Si dichiara che conforme a Es wird als konform mit den folgenden Normen erkl rt Se declara que est en conformidad con Nous d clarons sa conformit Hierbij wordt verklaar...

Reviews: