Dantherm iA/C T Series Information Manual Download Page 17

 

 iA/C T-Series Installation, Operating & Maintenance Manual 

AC-10 iAC 10K 12K Manual Rev D 

 

Page 17 of 18 

 

 
 

7

 

WARRANTY 

DANTHERM, INC., HEAT EXCHANGER AND AIR CONDITIONING UNITS LIMITED WARRANTY 

 

DANTHERM,  INC.’s  (“DANTHERM”)  limited  warranty  extends  to  the  original  purchaser  only  of  any  DANTHERM  
heat  exchanger  and  air  conditioning  unit,  and  to  no  other  person  or  entity.    DANTHERM  warrants  that  such 
DANTHERM products will be free from defects in materials and workmanship in normal use for a period of  twelve (12) 
months  from  the  date  of  the  original  purchase.    Should  any  part  of  your  DANTHERM  product  fail  because  of  a 
manufacturing defect within such twelve (12) month period, DANTHERM terms are set out below: 
 

PRODUCT WARRANTY 

SHIPMENT LIABILITY 

PRODUCT 

WARRANT
Y PERIOD* 

IN FIELD 
WARRANTY** 

RETURN TO BASE 
WARRANTY 

IN FIELD 

RETURN TO BASE 

 

 

 

 

 

 

AIR 
CONDITIONER 

12  months 

PARTS SUPPLY 
ONLY 

PARTS & LABOR 

Supply part freight pre-
paid by Dantherm. 
Return of defective part 
pre-paid by customer 

Return of item freight pre-
paid by customer 
Supply of item freight pre-
paid by Dantherm. 

 

 

 

 

 

 

HEAT 
EXCHANGER 

12 months 

PARTS SUPPLY 
ONLY 

PARTS & LABOR 

Supply part freight pre-
paid by Dantherm. 
Return of defective part 
pre-paid by customer 

Return freight pre-paid by 
customer 
Supply freight pre-paid by 
Dantherm. 

 

**

 

Using Dantherm nominated service contractors – warranty on product continues 

 

Using Dantherm non-approved service contractors – warranty on product becomes void 

Warranty period starts from date of dispatch – warranty of replacement parts shall only apply for the remainder 
of the warranty period of the original product. 

 

Any transportation, related service labor, diagnosis calls, filters, driers, and refrigerant are not included.  In the event all 
related  service  labor  is  performed  by  DANTHERM  nominated  service  contractors,  the  replacement  part  shall  be 
warranted by DANTHERM for the remainder of the warranty period of the original product. 

 
This  warranty  does  not  cover  damages  or  repairs  caused  by  improper  installation,  misuse  of  the  product, 
negligent servicing, improper applications, unauthorized modifications, improper electrical supply, failure to 
follow  manufacturer’s  instructions  and  rating  plate  information,  accidents,  natural  disasters,  damage  in 
transportation, lack of normal preventive maintenance, or other events beyond DANTHERM’s control.   This 
warranty is also subject to the following operating conditions:  1) voltage variation not greater than 10%, 2) 
frequency  variation  not  greater than 3Hz  from  nameplate rating, 3) cooling load is not  greater than product 
label under rated conditions 4) unit is not restarted for a period of five minutes after accidental or intentional 
shut-off, 5) operation is not subject to abnormal conditions or customer, user misapplication, 6) customer or 
user does not modify, abuse, or neglect the product, 7) refrigerant specified on nameplate is only refrigerant 
used,  and  8)  customer  or  user  complies  with  all  other  installation,  maintenance,  and  operating  instructions.  
Cost of repair or replacement of consumable parts is not covered under the terms of this warranty.   
 

THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER OF A DANTHERM PINNACLE HEAT EXCHANGER AND CLASSIC AIR 
CONDITIONING  UNIT  AND  IS  IN  LIEU  OF  ALL  OTHER  ARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING,  WITHOUT  LIMITATION,  ANY  IMPLIED 
WARRANTIES OF MERCHANTABILITY, FITNESS FOR USE, OR FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL ANY IMPLIED WARRANTIES OF 
MERCHANTABILITY, FITNESS FOR USE, OR FOR A PARTICULAR PURPOSE EXCEED THE TERMS OF THE APPLICABLE WARRANTY STATED ABOVE, 
AND  DANTHERM  SHALL  HAVE  NO  OTHER  OBLIGATION  OR  LIABILITY,  EXPRESS  OR  IMPLIED.    IN  NO  EVENT  SHALL  DANTHERM  BE  LIABLE  FOR 
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.   

 

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.  SOME 
STATES DO NOT ALLOW LIMITATIONS OR EXCLUSIONS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. 

 

 

 

Summary of Contents for iA/C T Series

Page 1: ...orate Drive Suite K Spartanburg SC 29303 Tel 1 864 595 9800 Fax 1 864 595 9810 Email dantherm usa dantherm com Website www dantherm com Panel Mounted Air Conditioners by Dantherm Inc iA C T Series iA...

Page 2: ...UNIT OPERATION 8 5 USACG 6 INTELLIGENT CONTROLLER OPERATION 9 5 1 USACG 6 CONTROLLER DIAGRAM 9 5 2 MODIFY HEATING SET POINT 9 5 3 MODIFY COOLING SET POINT 10 5 4 CHANGE UNIT OF MEASURE 10 5 5 DEBUGGIN...

Page 3: ...recognized and tested to UL484 It will comply where necessary with the safety requirements as defined in UL484 When servicing the unit do not remove the cover s for 5 minutes after switching the unit...

Page 4: ...prox Weight lbs Kg iA C T B10000 10 000 2928 230V 50 60 1 11 0 9 0 171 77 6 iA C T B12000 12 000 3514 230V 50 60 1 11 0 9 0 176 80 Rating capacity shown based on 95 F return air temperature to cabinet...

Page 5: ...iA C T Series Installation Operating Maintenance Manual AC 10 iAC 10K 12K Manual Rev D Page 5 of 18 4 DIMENSIONS INSTALLATION 4 1 Product Drawing 4 1 1 iA C T B10000 4 1 2 iA C T B12000...

Page 6: ...iA C T Series Installation Operating Maintenance Manual AC 10 iAC 10K 12K Manual Rev D Page 6 of 18 4 2 Mounting template 4 2 1 iA C T B10000...

Page 7: ...iA C T Series Installation Operating Maintenance Manual AC 10 iAC 10K 12K Manual Rev D Page 7 of 18 4 2 2 iA C T B12000...

Page 8: ...e sure a properly grounded power supply is used All installations are to be completed in accordance with local NEC codes and guidelines The electrical circuit should be protected by a slow blow breake...

Page 9: ...n application by accessing the controller via the RS 232 serial port connected to a PC with HyperTerminal Access the controller by removing upper front cover of the unit Adjusting the factory controll...

Page 10: ...Display Mode 2 Press L R button simultaneously for 2 seconds and release Display will show test 3 Press R button for 2 seconds and release Display will show H SP 4 Press R button for 2 seconds and re...

Page 11: ...test step 4 TEST steps STEP DESCRIPTION LED INT FAN HEATER COMP COND FAN DURATION 0 Display S W Revision Level X XX ON OFF OFF OFF 10 SEC 1 Int Fan only T01 ON OFF OFF OFF 30 SEC 2 Heater T02 ON ON OF...

Page 12: ...coils should be cleaned Once the coils become visibly coated with dust it is recommended that they be cleaned with a brush or compressed air Both sides of the coils should be inspected The condenser...

Page 13: ...ned to Dantherm Inc for servicing In the event that the unit cannot be returned it is possible using suitably qualified personnel to repair the unit in the field If the refrigerant charge is lost the...

Page 14: ...ssembly Condensate draining continuously Enclosure not properly sealed Check and seal all openings Excessive vibration Loose compressor fans or tubing Locate and correct Missing Compressor Current F 0...

Page 15: ...iA C T Series Installation Operating Maintenance Manual AC 10 iAC 10K 12K Manual Rev D Page 15 of 18 6 8 Wiring Diagram...

Page 16: ...iA C T Series Installation Operating Maintenance Manual AC 10 iAC 10K 12K Manual Rev D Page 16 of 18 6 9 Spare Parts Guide...

Page 17: ...the warranty period of the original product This warranty does not cover damages or repairs caused by improper installation misuse of the product negligent servicing improper applications unauthorize...

Page 18: ...m Inc part number s of product to be returned Dantherm Inc serial number s of product to be returned Number of units requested to be returned Reason for return Contact name phone and fax number Date o...

Reviews: