38
Fault finding guide,
continued
Inconvenience
Localise the problem in the left column and follow the instructions in the right column
Inconvenience
Cause
Action
Fan Step 4 is activated
(only suited for shorter
duration of use).
Turn the unit back to Fan Step
1, 2, 3 or activate Automatic
Demand Mode.
Abnormal noise from the
unit
The installation has not
been done correctly.
Contact to your installer to get
the unit correctly balanced
The unit is a HCV 3
which does not have a
built-in bypass-module.
There are no malfunctions.
The outside air might be
heated up before enter-
ing the house.
Contact to your installer.
The unit is not cooling suf-
ficiently.
The temperatures are
outside the established
limits, which must be
met in order to achieve
cooling with the help of
bypass. See the sec-
tion “Set points and
control strategies” in
the installation guide.
Activate Manual Bypass Mode
and cooling is active for the
next 6 hours.
Disparate operation, with
a large variation of the
volume of air.
The unit is probably set
on Automatic Demand
Mode which will vary
the volume of air ac-
cording to the needs in
the house and the hu-
midity level of the ex-
tract air.
It is recommended to set the
unit in Manual Operation
Mode and choose the fan step
which meets the demands
most optimal (normally Fan
Step 3).
It is not advisable to operate
with air flow rates beneath the
amount demanded by the
house with reference to national
law regulations, otherwise it can
create a risk of damage from
damp and reduced air quality.