![Dantherm calorex AW834 Owners & Installation Manual Download Page 31](http://html1.mh-extra.com/html/dantherm/calorex-aw834/calorex-aw834_owners-and-installation-manual_3496239031.webp)
HEAT PUMPS, SPECIALIST APPLICATIONS HEATERS
For Accurate Application Sizing Consult Dantherm Ltd.
NOTES:
1) Weight and dimensions nett
1mm WG = 9.8 Pa
2) Performance design limitation
1m hd = 1.4 psi
Water heating mode -
1L/min = 0.22 gall/min
Ambient = 10°C min 50°C max 1534BH 12°C min 30°C max
Water = 10°C min 50°C max 1534BH 15°C min 70°C max
3) Allow 500mm clearance to service panels
4) Water to have correct balance. pH 6.6 - 8.5
5) Dantherm Ltd. reserves the right to change or modify models without prior notice
6) Global warming potential (GWP) R134a 1430
MODEL
3Ø AW3034KH(F)
3Ø AW7034KH(F)
3Ø AW3034KHY(F)
3Ø AW7034KHY(F)
UNITS
DUTY
@ Air On 30°C, 90%RH
kW
29.2/25.7
46.2/40.7
29.2/25.7
46.2/40.7
Electrical Input
kW
6.4/9.9
9.8/15.4
6.4/9.9
9.8/15.4
@ Air On 20°C, 65%RH
kW
26.5/24.0
42.0/37.4
26.5/24.0
42.0/37.4
Electrical Input
kW
5.7/8.6
8.7/13.4
5.7/8.6
8.7/13.4
@ Air On 10°C, 85%RH
kW
22.4/20.0
35.0/31.7
22.4/20.0
35.0/31.7
Electrical Input
kW
5.4/8.1
8.2/12.5
5.4/8.1
8.2/12.5
@ Air On 0°C, 90%RH
kW
N/A
N/A
15.6/13.7
24.7/21.7
Electrical Input
kW
N/A
N/A
4.9/7.4
7.5/11.5
ELECTRICAL DATA
Electrical Supply 3 Phase
V/ph/Hz
|----------------------------------------400V / ~3N / 60Hz----------------------------------------|
Minimum Supply Capacity 3 Phase
A
26
30
26
30
Recommended Supply Fuse 3 Phase
A
40
45
40
45
Max Starting Current STD (LRA)
A
153
72
153
153
Max Starting Current S/Start (LRA)
A
38
30
38
38
AIR DATA
Nominal Air Flow
m3/h
10000
12500
10000
12500
Fan External Resistance (Standard Unit)
Pa
0
0
0
0
Fan External Resistance 'F' (Uprated Unit)
Pa
Variable to 250
Variable to 250
Variable to 250
Variable to 250
WATER DATA
Water Flow ±10%
L/min
66
130
66
130
Pressure Drop (Water)
m hd
4·5
3·9
4·5
3·9
Water Connections
inches
|----------------------------------------1½" BSPM----------------------------------------|
Condensate Water Connections
inches
|----------------------------------------1½" BSPM----------------------------------------|
GENERAL DATA
HERMETIC SYSTEM
Gas Charge (R134a)
kg
15
28
17
30
Sound Pressure Level @3m
dB A
69
68
69
68
DIMENSION DATA
Width (unpacked)
mm
1700
1950
1700
1950
Depth (unpacked)
mm
1090
1340
1090
1340
Height (unpacked)
mm
1212
1212
1212
1212
Weight (unpacked)
kg
393
569
399
584
31
SD331851 ISSUE 28