background image

CAUTION

Install or remove modules from the shelf only when the power is off.

If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.

Remove and install circuit boards only in a static-safe environment

(use antistatic wrist straps, smocks, footwear, etc.).

Keep circuit boards in their antistatic bags when they are not in use.

Do not ship or store circuit boards near strong electrostatic, electromag-

netic, magnetic, or radioactive fields.

For more complete information on electrostatic discharge safety

precautions, refer to Bellcore

TM

 Technical Reference # TR-NWT-000870.

Copyright 1999 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered

Printed in the U.S.A.

I

NSTALLATION

 & O

PERATION

 M

ANUAL

46035-01-1297 <90-00071>

Issue date:

Reissued Practices: Updated and
new content can be identified by a
banner in the outside margin.

UPDATED

Table of Contents

Ordering Information ...........................................................................  2

General Description ..............................................................................  2

Circuit Description ...............................................................................  3

Application Information .......................................................................  5

Installation ............................................................................................  8

Technical Specifications .....................................................................  12

Operation ............................................................................................  12

Warranty .............................................................................................  14

46035-01

C

ONVERTER

 M

ODULE

XMT

RCV

XMT

DATA

46035-01

CONVERTER

MODULE

XMT

RCV

A11-46035-01 REV__

About this Practice:

This practice has been reissued to:
• Incorporate addendum into

Application Information section.

Summary of Contents for 46035-01

Page 1: ...ischarge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1999 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A I...

Page 2: ...sts Dantel s most common communications subassemblies The 46035 also provides external input output of the intermedi ate TTL data The 46035 is a plug in printed circuit board that fits into any Dantel...

Page 3: ...or s collector is shunted directly to the emitter which is grounded and grounds the RTS pin 42 of the module and pin P5 12 of the subassembly When the RTS switch is OFF the transistor s base receives...

Page 4: ...ROM SUBASS Y P5 J5 GND 21 TO 56 VDC TXD RTS CTS RXD DCD S1 2 S1 1 S1 4 S1 6 S1 5 S1 8 10 12 DCD DATA CA RS 232 CF XMT 4 2 RCV A B RS 232 STRAP 6 DATA RTS DATA INPUT OUTPUT CONVERSION LOGIC RS 422 RS 4...

Page 5: ...ER PROGRAMED TO ACT AS A DUMB TERMINAL The 46035 is also used to interface the printer port RS 232 of the MAP to an E2A remote polling TBOS Refer to Fig 3 Also shown is the 46035 being used to interfa...

Page 6: ...CURRENT LOOP INTERFACE SUBASS Y RS 232 RS 422 E2A REMOTE PRINTER PORT TTL LOCATION 2 LOCATION 1 TX RX 46035 01 46035 01 MAC 46022 12 RS 422 MAT W 49009 MAT W 49009 56 53 18 56 53 18 CA CA RS 232 53 5...

Page 7: ...ONE MODEM 202 202 49008 RS 422 CURRENT LOOP RS 422 CENTRAL LOCATION BUILDING B 2 0 2 B Y P A S S MAT B Y P A S S CPM TTL MAT MAT MAT CM MAT MAT B Y P A S S FLOOR 2 B Y P A S S CPM CPM CPM CPM CPM B Y...

Page 8: ...Tables A and B The 46035 Converter Module has an eight switch mini DIP that configures the unit for differ ent applications Configure the unit for RS 232 RS 422 or RS 485 data communications interfac...

Page 9: ...485 input Selects RS 422 485 interface output Selects RS 232 interface output TABLE B POSSIBLE INTERFACE COMBINATIONS 1 2 3 4 5 6 7 8 9 SOURCE 00 00 00 TTL TTL TTL RS 232 RS 422 RS 485 DESTINATION TTL...

Page 10: ...slot in the equipment shelf In most cases the shelf will be pre wired for the 46035 Con verter Module If necessary refer to Fig 7 for module pin designations 4 Align the modem subassembly if installed...

Page 11: ...RD DTR DCD RS 422 485 TX TX RX RX NOTE Available only with 49029 communications subassembly CTS RXD TXD TXD RXD NOTE w TTL RS 232 422 function is reversed DCD RTS RTS DCD NOTE Designation shown for D...

Page 12: ...035 Converter Module has two front panel LED indica tors The green LED labeled XMT flashes when data is trans mitted The yellow LED labeled RCV flashes when data is received OPERATION TECHNICAL SPECIF...

Page 13: ...46035 01 1297 90 00071 PAGE 13 NOTES...

Page 14: ...ten instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respe...

Reviews: