background image

P

AGE

 4

46032-15-0198 <90-00070>

OPERATION

T

he relays operate on any battery voltage from -5 to -60 VDC.

There is no latching capability. The relay contacts open when

voltage is removed. The individual LED should light on the front
panel as power is applied to each relay. This, however, does not
verify correct relay contact operation — only that power is
applied to that individual relay coil.

TECHNICAL SPECIFICATIONS

DESCRIPTION

Input Voltage Range
Current Requirements

No relays Operating
One Relay Enabled
All Relays Enabled

Heat Dissipation

One Relay Enabled
All Relays Enabled

Current per Input to Operate
Control Lead Input Voltage

Minimum Operating
Maximum Release

Relay Contacts

Current Rating
Resistance

Operating Temperature
Physical Dimensions
Weight

DESCRIPTION

-21 to -56 VDC
@ -21VDC

@ -24 VDC

@ -48 VDC

@ -56 VDC

0.0 mA

0.0 mA

0.0 mA

0.0 mA

7.0 mA

8.0 mA

11.0 mA

12.0 mA

112.0 mA

128.0 mA

176.0 mA

192.0 mA

@ -21VDC

@ -24 VDC

@ -48 VDC

@ -56 VDC

0.50 Btu/Hr

0.66 Btu/Hr

1.8 Btu/Hr

2.3 Btu/Hr

8.0 Btu/Hr

10.5 Btu/Hr

28.8 Btu/Hr

36.7 Btu/Hr

0.13 mA @ -5 VDC; 2.75 mA @ -60 VDC

-2.75 VDC
-1.5 VDC

1 Amp @ 30 VDC
0.1 Ohm
0° to 55° C.
1.4" x 6.0" x 5.6"
7.5 Ounces

Reviews: