TECHNICAL SPECIFICATIONS

DESCRIPTION

Input Voltage

INPUT CURRENT (+10%)

Thru-Hole Version

@ -21 VDC
@ -24 VDC

@ -48 VDC

@ -56 VDC

SMT Version

@ -21 VDC

@ -24 VDC
@ -48 VDC

@ -56 VDC

HEAT DISSIPATION (+10%)

Thru-Hole Version

@ -21 VDC

@ -24 VDC
@ -48 VDC

@ -56 VDC

SMT Version

@ -21 VDC

@ -24 VDC

@ -48 VDC
@ -56 VDC

Output Voltage and Current

DATA RATES

Master Port
Data Port

Physical Dimensions
Weight

Operating Temperature Range

VALUE

-21 to -56 VDC

300 mA
268 mA

155 mA

140 mA

133 mA

120 mA

62 mA

55 mA

21.5 Btu/Hr

21.9 Btu/Hr
25.4 Btu/Hr

26.8 Btu/Hr

9.53 Btu/Hr

9.82 Btu/Hr

10.14 Btu/Hr
10.50 Btu/Hr

+5 VDC @ 200 mA

+12 VDC @ 20 mA

-12 VDC @ 20 mA

1200, 9600 baud

75, 110, 150, 300, 600, 1200,

2400, 4800, 9600 baud

1.4" x 6.0" x 5.6"

10.5 ounces

0° to 55° C.

UPDATED

Summary of Contents for 46023-12

Page 1: ...charge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1999 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INS...

Page 2: ...one is a 46023 12 Smart MAC all the others must be 46023 12 Smart MACs as well You cannot use the 46023 12 Smart MAC in combination with 46022 12 20 or 30 MACs Here are some features of the 46023 Sma...

Page 3: ...d through RS 422 drivers and receivers The receive lines have an optional strap selection for 100 ohm termination The configuration of the MAP determines the data rate and proto col of each port The m...

Page 4: ...ACE 51 54 53 42 45 44 43 36 56 55 50 45 49 47 POWER SUPPLY SUBASSEMBLY 17 35 DISPLAY DRIVER FRONT PANEL LEDs AND SWITCHES CARD SELECT CHANNEL SELECT DISPLAY CONTROL TO MATs CPMs ETC PORT 2 TX RX TX RX...

Page 5: ...n If a channel is connected to communications lines the resistor is normally strapped IN position 1 2 If termination for a channel is provided at the source strap the resistor OUT Refer to Table A and...

Page 6: ...source switch the resistor OFF Refer to Table B and Fig 3 TABLE B RECEIVE LINE TERMINATION SMT VERSION FIG 3 SWITCH AND STRAP OPTION LOCATIONS SMT VERSION INSTALLATION ALARM PORT NUMBER 1 2 3 4 5 6 7...

Page 7: ...the master port data rate for 9600 baud Master Port Protocol Switches S1 5 through S1 8 Unless system requirements dictate otherwise set the master port protocol to DCPF Port Termination SMT Version O...

Page 8: ...S2 Not Used SWITCH S3 SMT VERSION ONLY PortTermination Port 1 Terminated Port 2 Terminated Port 3 Terminated Port 4 Terminated Port 5 Terminated Port 6 Terminated Port 7 Terminated Port 8 Terminated...

Page 9: ...ble 12 VDC Output WRT 12 VDC Output Serial Output Data 5 VDC Output MAP Channel Address 0 MAP Channel Address 2 MAP Channel Address 3 TXD Modem Data Connection MAP Channel Address 1 21 to 56 VDC Alarm...

Page 10: ...and other functions Four green LEDs labeled A B C and D have various func tions Refer to the documentation specific to the MAP firm ware One green LED labeled RX DATA indicates that the data ports are...

Page 11: ...sion 21 VDC 24 VDC 48 VDC 56 VDC OutputVoltageandCurrent DATA RATES MasterPort Data Port PhysicalDimensions Weight OperatingTemperatureRange VALUE 21 to 56 VDC 300 mA 268 mA 155 mA 140 mA 133 mA 120 m...

Page 12: ...en instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respec...

Reviews: