Dantel 46019 Installation & Operation Manual Download Page 9

46019-0298 <90-00028>

 P

AGE

 9

TECHNICAL SPECIFICATIONS

DESCRIPTION

Input Power

Voltage
Current

Idle (All relays and LEDs off)
Operating (All relays and LEDs on)

Alarm Circuit Inputs (A-D, O.C., TTL)

Normal
Alarm

Reset

Normal
Reset

External Acknowledge In

Optically Coupled

Normal
Acknowledged

TTL

Normal
Acknowledged

Common External Acknowledge

Input To Operate

Relay Contact Rating

@ 30 VDC
@ 125 VAC

Physical Dimensions
Weight
Operating Temperature Range

VALUE

-21 to -56 VDC

55 mA (min.), 62 mA (max.)
152 mA (min.), 172 mA (max.)

+5 to +1.4 VDC
0 to +1.4 VDC

+5 to +1.4 VDC
0 to +1.4 VDC

(-) Battery
Ground

+5 to +0.7 VDC
0 to +0.7 VDC

0 to +1.4 VDC

2.0 Amps
0.5 Amps
1.4" x 6.0" x 5.6"
10.75 ounces
0° to 55° C.

Summary of Contents for 46019

Page 1: ...NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INSTALLATION OPERATION MANUAL 46019 0298 90 00028 46019 SUMMARY ALARM M...

Page 2: ...nto any 400 type or similar equipment housing The SAM does not accept subassem blies The SAM operates on 21 to 56 VDC input power CIRCUIT DESCRIPTION Fig 1 shows the 46019 Summary Alarm Module functio...

Page 3: ...nergizes that individual level relay s operating coil Each relay has two sets of relay contacts visual and audible Each set has normally open NO and normally closed NC contacts The common relay operat...

Page 4: ...45 56 VISUAL CONTACTS AUDIBLE CONTACTS OUTPUT RELAYS N O COMM N C BATT 10K OFF 54 24 VISUAL CONTACTS AUDIBLE CONTACTS COMMON RELAY COMM BATT SWITCH TIME SELECTOR Set only one switch on 0 5 1 4 8 TTL O...

Page 5: ...trolled by the SAM s relays on another floor for example the central office The external indicators on another floor act independently of the alarm shelf processor The alarm shelf processor reports to...

Page 6: ...hes in the ON position Straps determine whether the relays follow the inputs or the latch FIG 3 SWITCH AND STRAP LOCATIONS 46019 SAM TABLE A SWITCH SETTINGS 46019 SAM OPTION Switch 1 ON all others OFF...

Page 7: ...evel A TTL Input Level A Visual Relay Common Level A Visual Relay N C Level A Visual Relay N O Level A Optically Coupled Input Level B TTL Input 21 to 56 VDC Input Level B Optically Coupled Input Leve...

Page 8: ...part operation of the 46019 Summary Alarm Module consists of observing the LEDs or operating one of the front panel Alarm Cut Off ACO switches Interrupt alarm signaling by moving the appropriate fron...

Page 9: ...owledge In Optically Coupled Normal Acknowledged TTL Normal Acknowledged Common External Acknowledge Input To Operate Relay Contact Rating 30 VDC 125 VAC Physical Dimensions Weight Operating Temperatu...

Page 10: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Reviews: