4. Install the module in the proper slot in the equipment
shelf.

The 46017 is usually installed in a pre-wired Dantel shelf. Refer
to Fig. 8 if custom wiring is required.

F

IG

. 8 - P

IN

 D

ESIGNATIONS

, 46017

INSTALLATION

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

CIRCUIT SIDE
OF PC BOARD

COMPONENT SIDE

OF PC BOARD

K1-B-NOR, Open

K1-B, Common

K1-A-NOR, Open

K1-B-NOR, Closed

Circuit 5, O.C. Input

K1-A-NOR, Closed

Circuit 6, O.C. Input

K1-A, Common

Circuit 8, O.C. Input

Circuit 7, O.C. Input

K2-B-NOR, Closed

K2-B-NOR, Open

K2-A-NOR,Open

K2-B, Common

Group 1, Acknowledge In

K2-A-NOR, Closed

Circuit 2, TTL Input

K2-A, Common

Circuit 4, TTL Input

Circuit 3, TTL Input

-21 to -56 VDC

Circuit 1, TTL Input

Circuit 3, O.C. Input

Circuit 1, O.C. Input

External Acknowledge

Circuit 2, O.C. Input

External Acknowledge

Circuit 4, O.C. Input

Group 1 Acknowledge Button

Group 1 Acknowledge Button

Circuit 10, O.C. Input

Circuit 11, O.C. Input

Circuit 12, O.C. Input

Circuit 10, TTL Input

Circuit 9, O.C. Input

Circuit 9, TTL Input

Circuit 12, TTL Input

Circuit 11, TTL Input

Ground

K4-A, Common

Group 2 Acknowledge In

K4-A-NOR, Closed

K4-B, Common

K4-A-NOR, Open

K4-B-NOR, Closed

Circuit 13, O.C. Input

K4-B-NOR, Open

Circuit 14, O.C. Input

Circuit 15, O.C. Input

K3-A, Common

Circuit 16, O.C. Input

K3-A-NOR, Closed

K3-A-NOR, Open

K3-B-NOR, Closed

K3-B-NOR, Open

K3-B, Common

Summary of Contents for 46017

Page 1: ...fer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of Dantel Inc ISO 9001 Registered Printed in the U S A INSTALLATION OPERATION MANUAL 4...

Page 2: ...ogether and audibly recognized The 46017 SAAM also provides relays to control external audio and visual alarm indicating devices A timer can be set to acknowledge all alarms automatically There are tw...

Page 3: ...button will acknowledge alarms on the 46017 SAAM and all modules to which the switch is wired Set the DIP switches to acknowledge alarms automatically after a certain time out period refer to Table A...

Page 4: ...E 4 46017 0398 90 00006 FIG 1 FUNCTIONAL SCHEMATIC 46017 K4 K3 AUTOMATIC ALARM ACKNOWLEDGEMENT CIRCUIT TTL OC TTL OC TTL OC TTL OC OC OC OC OC TTL OC TTL OC TTL OC TTL OC OC OC OC OC CIRCUIT DESCRIPTI...

Page 5: ...alarms will reactivate the relays and audible alarm and restart the timer When the time out function is not used the relays and audible alarm remain active until you acknowledge the alarms Audio Driv...

Page 6: ...provides a different audio and or visual signal Two groups use the 46017 SAMM on board Sonalert The other two control an external audio or visual device with their alarm enabled relays K1 B pins 56 an...

Page 7: ...pplication can use up to 16 MATs Level A outputs with the greatest priority should connect to Group 2 because that group always precedes Group 1 FIG 3 SINGLE LEVEL ALARM REPORTING APPLICATION ALARM OU...

Page 8: ...group TTL inputs for in shelf applications only FIG 4 SINGLE LEVEL OR MULTIPLE LEVEL ALARM REPORTING APPLICATION 46017 SUMMARY AUDIBLE ALARM MODULE 46020 MULTIPLE ALARM PROCESSOR DATA PORT Subassembl...

Page 9: ...losed NEW relay contact does not signal the external device If the NEW relay drops the EXIST relay does not signal the external device The built in audible device continues operating until it times ou...

Page 10: ...LEDs and releases the NEW relays After the time out period any new alarms will reactivate the relays and audible alarm and restart the timer When the time out func tion is not used the relays and audi...

Page 11: ...re the relays to external audio and visual alarm indicating devices One method is shown in Fig 7 where external devices follow the alarms or acknowledgment by chaining the EXIST and NEW relays togethe...

Page 12: ...OR Closed K2 B NOR Open K2 A NOR Open K2 B Common Group 1 Acknowledge In K2 A NOR Closed Circuit 2 TTL Input K2 A Common Circuit 4 TTL Input Circuit 3 TTL Input 21 to 56 VDC Circuit 1 TTL Input Circui...

Page 13: ...ates which of the 16 alarm inputs has an alarm present The lower row of LEDs in each alarm group NEW indi cates an alarm that has not been acknowledged You can acknowledge alarms in one of several way...

Page 14: ...125 VAC Alarm Input Requirements TTL Inputs Optically Coupled Inputs Audio Alarm Type and Frequency Temperature Range Physical Dimensions Weight VALUE 21 to 45 VDC 50 mA 40 mA 250 mA 280 mA 3 6 Btu Hr...

Page 15: ...46017 0398 90 00006 PAGE 15 NOTES...

Page 16: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Reviews: