P

AGE

 2

44214-0898 <90-00005>

ORDERING INFORMATION

NOTE: This section lists the different options available for this product. To order any of the avail-

able options, contact Dantel Inside Sales through our toll-free number, 1-800-432-6835.

OPTION NUMBER

FEATURES

A11-44214-00

9600 bps Tone Modem

GENERAL DESCRIPTION

T

he A11-44214-00 9600 bps Modem is a 400-type module used

in applications where a tone modem is required. This module

provides an interface between  Data Terminal Equipment (such
as a computer or terminal) and a  4-wire voice channel (such as
a mux channel or a satellite link). Capable of transmitting and
receiving data at 1200, 2400, 4800, or 9600 bps, this module
converts asynchronous data from a serial bit stream into voice-
frequency tone in one direction and tone to serial data in the
other direction.

On the data side of the 44214 there are input/output ports
available for interfacing to Data Terminal Equipment. Available
interfaces are:

TTL/CMOS

RS232

RS422

RS485

An on-board switch (S6) selects which interface is enabled.

The front panel provides:

Four mini jacks for 4-wire level adjustments and testing.

Six green LEDs that indicate communication status.

Switches for testing the modem, and selecting the mode of
operation.

Potentiometers for adjusting the transmit and receive levels.

N

OTE

:

The 44214 must communicate
with another 44214. Using on-
board switches, set the baud rate
of both modules the same.

N

OTE

:

Only one interface may be en-
abled at a time.

N

OTE

:

The A11-44214-00 4-Wire Modem
is not Bell 202 compatible.

Summary of Contents for 44214

Page 1: ...elds For more complete information on electrostatic discharge safety precautions refer to BellcoreTM Technical Reference TR NWT 000870 Copyright 1998 by Dantel Inc Dantel is a registered trademark of...

Page 2: ...odule converts asynchronous data from a serial bit stream into voice frequency tone in one direction and tone to serial data in the other direction On the data side of the 44214 there are input output...

Page 3: ...sition switch S3 is used to enable or disable the analog side A second two position switch S5 is used to enable or disable the digital side Modem Controller The modem controller provides all the modem...

Page 4: ...ugh the front panel S1 S3 S4 S5 R44 R53 S4 5VDC JP4 JP5 RTS DTR INTERFACE ENABLE JP1 S6 T O JP2 TTL CMOS SIGNAL GROUND RS 232 RS 422 DTR RTS TD RD CD CTS DSR TD DTR CTS RTS CD RD DSR TX TX RTS RTS CD...

Page 5: ...0dBm and 0dBm INSTALLATION Installation consists of setting the switch and strap settings wiring the pin connectors installing the module in the shelf and checking out the module 1 Set the switch and...

Page 6: ...module be removed from the shelf or replaced in the shelf remove power from the entire shelf RTS DTR Remove power and set JP4 to ACT Replace the module and restore power The front panel DTR LED will i...

Page 7: ...s character back FINAL CHECK OUT For the two modems to communicate with each other one must be set to ORG mode and the other to ANS These switches are on the front panel of each unit Make sure that th...

Page 8: ...Disable digital loopback RS 232 I O Port enabled TTL CMOS I O Port enabled RS 422 I O Port enabled RS 485 I O Port enabled 4 Wire operation 2 Wire operation NOTE Enable only one I O port at a time JP4...

Page 9: ...LB TTL 4 Wire RCV or 2 Wire XMT RCV 4 Wire RCV or 2 Wire XMT RCV 4 Wire XMT 4 Wire XMT 21 to 56 VDC DTR TTL RTS TTL RD TTL TD TTL CTS TTL CD TTL Signal Ground DSR TTL TD RS 232 DTR RS 232 RTS RS 232 G...

Page 10: ...214 9600 bps Modem consists of observing the front panel LEDs Six green LEDs on the 44214 front panel indicate TD Transmit Data RD Receive Data RTS Request To Send CD Carrier Detect DTR Data Terminal...

Page 11: ...S DEDICATED COPPER PAIR REMOTE LOCATION LOCAL MONITORING AND CONTROL DISCRETE ALARM POINTS FIG 6 EXAMPLE APPLICATION 2 41096 01 41096 01 MASTER CALLING TERMINAL DATA CIRCUIT REMOTE CALLED TERMINAL FIB...

Page 12: ...Resistance RS 422 RS 485 Receivers Differential Input Common Mode Input Drivers Differential Output Short Circuit Current ALB DLB Inputs Operating Voltage Usable Voltage VALUE 21 to 56 VDC 114 mA 100...

Page 13: ...ud Symbol Sec Bits Per Symbol Data TCM Constellation Points 9600 V 32 9600 QAM 1800 2400 4 0 16 7200 V 32 TCM TCM 1800 2400 3 1 16 4800 V 32 4800 QAM 1800 2400 2 1 4 2400 V 22 BIS 2400 QAM 1200 2400 6...

Page 14: ...n instrument signed by a duly authorized officer of the Seller and accepted by the Buyer Warranty and remedies on products not manufactured by the Seller are in accordance with warranty of the respect...

Reviews: