NOTE
: In Fig 7, Port 1 of the first module is the summing port and
ports 2, 3, and 4 are distribution ports and are strapped as described
above. All the ports on the other modules are distribution ports and
each module is strapped as follows:
D1R, D1X, G1X
D2R, D2X, G2X
D3R, D3X, G3X
D4R, D4X, G4X
OPTION
GAIN STRAPS
Receive Port 1
0 to -16 dB
0 to +7 dB
Receive Port 2
0 to -16 dB
0 to +7 dB
Receive Port 3
0 to -16 dB
0 to +7 dB
Receive Port 4
0 to -16 dB
0 to +7 dB
Transmit Port 1
0 to +7 dB
0 to -16 dB
Transmit Port 2
0 to +7 dB
0 to -16 dB
Transmit Port 3
0 to +7 dB
0 to -16 dB
Transmit Port 4
0 to +7 dB
0 to -16 dB
STRAP IN
1R HI
1R LO
2R HI
2R LO
3R HI
3R LO
4R HI
4R LO
1X HI
1X LO
2X HI
2X LO
3X HI
3X LO
4X HI
4X LO
NOTE
: Check the drawings for your application to determine which
of the four ports is the summing port, then strap the module
accordingly.
PORT 1 SUMMING
(Ports 2, 3, & 4
Distribution)
D1R, D1H, B1X
H2R, D2X, G2X
H3R, D3X, G3X
H4R, D4X, G4X
PORT 2 SUMMING
(Ports 1, 3, & 4
Distribution)
H1R, D1X, G1X
D2R, D2H, B2X
H3R, D3X, G3X
H4R, D4X, G4X
PORT 3 SUMMING
(Ports 1, 2, & 4
Distribution)
H1R, D1X, G1X
H2R, D2X, G2X
D3R, D3H, B3X
H4R, D4X, G4X
PORT 4 SUMMING
(Ports 1, 2, & 3
Distribution)
H1R, D1X, G1X
H2R, D2X, G2X
H3R, D3X, G3X
D4R, D4H, B4X
INSTALLATION
T
ABLE
E - S
UMMING
AND
D
ISTRIBUTION
A
PPLICATION
S
TRAP
O
PTIONS