29
1) Title position is optional: bottom, top;
2) Character, time, character and time, blank are optional for display model;
3) To move cursor to position need to be changed, then press “enter” to choose display
model.
Alarm association setting:
Matrix system can connect to alarm input or alarm output equipments, user may combine
alarm signal with video signal together through programming, following picture is
sub-menu.
All data choose range:
Alarm address:
1-128 channel optional
Video Output:
1-16 channel optional
Dwell time:
1-99 second optional
Association
Invalid, valid
Video Input:
1-128 channels optional
Arming Method:
Manual, timed, often
Explanation for alarm association:
User may set alarm association for any alarm spot, if setting is right, once there is alarm
happen, matrix will carry out following commands:
1)
“Video image” displayed on appointed monitor would be automatically switched to
display image of video association on appointed monitor.
2)
If image of video association is more than one, matrix will auto switch images one by
one.
3)
When matrix switch images one by one, dwell time for each is number of “dwell time”
(unit: second)