Dante DLH6420 Installation And Operation Manual Download Page 8

 

 

5.0 OPERATION 

 

The DLH6420 unit works as a distribution repeater for expanding one RS-
422  communication  port  into  16  isolated  and  buffered  RS-422  ports.  The 
primary  use  for  the  DLH6420  is  to  provide  quick,  easy,  and  proper  data-
line distribution for serial type pan/tilt and dome receivers. In the case of 
these  isolated  RS-422  drive  lines,  the  remote  devices  may  be  located  as 
far  as  4,000  feet  (1,219  m)  away  from  the  controller,  depending  on  the 
physical  parameters  of  the  connection.The  unit  is  ideal  for  use  on  larger 
switching  systems  where  it  becomes  desirable  to  “home-run”  the  RS-422 
data lines for controlling pan/tilt or dome receivers. 
 

6.0 SPECIFICATIONS 

 

ELECTRICAL 

Input Voltage:  

   

  120/230 VAC, 50/60 Hz, auto-ranging, or 

                         Independent external source, 10-24 VAC/VDC 

Consumption:  

   

   30 vA 

Data Ports 
Input:          

   

      One RS-422, RJ-45 female connector 

Output:        

   

      One RS-422, RJ-45 female connector 

Drive Lines:    

   

    Sixteen 3-position screw-terminals with mating plugs 

Fusing:       

   

        500 mA, 250 V 

Indicators:     

   

     1 power LED, green 

                          1 data LED, red 

MECHANICAL 

Dimensions:    

Base Only:         1.75" H x 17”W x 8”D (4.45 x43x20. 45 cm) 
With Rack Ears:  1.75" H x 19”W x 8”D (4.45 x48.26x20. 45 cm) 

Operating 

Temperature:  

 

32° to 122°F (0° to 50°C) 

Weight:       

 

    6.6 lb (3 kg) 

GENERAL 

Mechanical 
Connectors 
Power:                     AC power cord input, 3-wire, #18 AWG 
                               2-pin screw terminal with mating plug for external   
                               power source 
RS-422:                   Two RJ-45, female 
RS-422                    Breakout 
Ports:                      Sixteen 3-pin headers with mating plug; connectors can  
                             accept 14–28 AWG 
(Design and product specifications subject to change without notice.) 

 

NOTE: If external AC transformer is used, it must be capable of supplying 
at least 8 watts. DC source can be hooked up without regard to polarity.  

Summary of Contents for DLH6420

Page 1: ...DLH6420 Code Distributor Installation and Operations Manual Model Number DLH6420 Description PTZ Control Code Data Distributor...

Page 2: ...CERTIFICATIONS 4 3 0 PRE INSTALLATION INFORMATION 5 3 1 FRONT VIEW 5 3 2 REAR VIEW 5 4 0 INSTALLATION 7 5 0 OPERATION 8 6 0 SPECIFICATIONS 8 LIST OF ILLUSTRATIONS Figure Page 1 DLH6420 Front View 5 2...

Page 3: ...rence to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television r...

Page 4: ...additional daisy chained unit Sixteen 3 position screw terminal connectors used to output 16 RS 422 transmit only code lines Two pin terminal connector refer to figure 3 for an external 10 to 24 VAC...

Page 5: ...power is applied to the unit the data LED will light when a transmission from the controller is received by the DLH6420 3 2 REAR VIEW Figure 2 illustrates the rear working side of the DLH6420 unit No...

Page 6: ...ource Figure3 DLH6420 Rear View Connector Details PIN1 PIN8 IN PIN1 PIN8 OUT RJ45 COMMUNICATION CONNECTORS IN INPUT FROM CONTROL UNIT OUT USED FOR CABLING SUBSEQUENT UNIT AC LINE CORD INPUT 100 240VAC...

Page 7: ...ut with one unit eight units may be daisy chained together This will allow 128 receivers that support 128 address settings to be connected on a single Sercom port Figure 4 illustrates two units daisy...

Page 8: ...dent external source 10 24 VAC VDC Consumption 30 vA Data Ports Input One RS 422 RJ 45 female connector Output One RS 422 RJ 45 female connector Drive Lines Sixteen 3 position screw terminals with mat...