DanPure LUXE 75 User Manual Download Page 4

2. Product brief introduction

2.1 Product configuration and technical parameters

2

.

2 Structure

1.

Display & Buttons

This area shows a general working status of the machine and buttons for different functions.

2.

Hot water tap

If you want to get hot water, you can put cup or glass under it, and push the red lever, while
at the same time, push the button above

3.

Normal water tap

If you want to get normal water, you can put cup or glass under it, and push the yellow lever.
4.Cold water tap
If you want to get cold water, you can put cup or glass under it, and push the blue lever.

5.

Drip tray

This is a tray for holding a little waste water. You can take it out when it is full.

6.

Lower panel

The lower panel is the cover for filters, can be disassembled for filters change. Please refer
to the instructions for filters replacement.

8.

Cooling power switch

Switch on to start the water cooling.

9.

Heating power switch heating.

Switch on to start the water heating
10.Condenser
This is part of cooling elements connect to compressor
11.Cold water outlet
It is used the first time you use the machine or long time without using it. You can screw out
the cap to release the water from the cold tank to clean the tank .

12.

Hot water outlet

It is used the first time you use the machine or long time without using it. You can screw out
the cap to release the water from the hot tank to clean the tank.

13.

Water inlet

It is connected with a PE tube to water tap, water then will come from your tap water into the
machine

14.

Drain water outlet

There will be some drain water coming out from this outlet when machine operates

Model

DANPURE LUXE 75

Description

Hot and cold water dispenser

Mode type

RO system

Power

220-240V

/

50Hz

Rated power

640W

Heating capacity

6L/H (    90

'

C

)

Cooling capacity

2L/H (    10

'

C

)

Applicable water quality

Municipal tap water

Applicable water pressure

0.1-0.6 Mpa

Ambient temperature

5-38

'

C

Package size

320x360x933 mm

Summary of Contents for LUXE 75

Page 1: ...RO WATER DISPENSER USER MANUAL please read this manual carefully Model DANPURE LUXE 75 ...

Page 2: ... must be replaced by the manufacturer its service agent or a similarly qualified person in order to avoid a hazard 3 The new hose sets supplied with the appliance are to be used and that old hose sets should not be reused 4 Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance 5 To avoid a hazard due to instability of the appliance it must be fixed in...

Page 3: ...eplace it Please must install the product as this user manual s request to avoid accident caused by product unsteady Do not make the machine inversion or till exceed 45 C After installed moved and severely shaken about 30 minutes are needed for stabilization of the compressor before using the product Never splash the product with water directly to avoid the short circuit or electric shock Do not d...

Page 4: ...start the water cooling 9 Heating power switch heating Switch on to start the water heating 10 Condenser This is part of cooling elements connect to compressor 11 Cold water outlet It is used the first time you use the machine or long time without using it You can screw out the cap to release the water from the cold tank to clean the tank 12 Hot water outlet It is used the first time you use the m...

Page 5: ...e water tank fully filled with water and drain all water do it again Then you can use unit normally adjust the feet to stabilize the machine connect the ball valve connect the PE tube to input connection 4 Maintaining 4 1 water tank cleaning a Connect one side of the CCK tube to the water inlet and the other side to water tap with a ball valve and a tri way socket b Plug in and turn on the water i...

Page 6: ...r 2 Keep pressing the insert of the quick connector and pull out the CCK pipe 3 The blue clamp ring need to be take out also when you want to take out the quick connector from the old filter At the same time you need to keep pressing the insert of the quick connector by using a straight screwdriver Note The CCK pipe must be in place about 17mm when stick it into the quick connector otherwise it ma...

Page 7: ...ell as heavy metal particles Stage 3 CTO It takes out 99 of the chlorine and organic chemicals It provides enhanced reduction of taste Odor and color Stage 4 RO A thin film composite high quality membrane that processes 50 gallons per day It removes the following hard water contaminants that may be present in your water lead cooper barium chromium mercury sodium cadmium fluoride nitrite and seleni...

Page 8: ...lug seat as requested e Disassemble the product by yourself or not install it as the requirements in the user manual f Not use the product as the requirements in the user manual 8 Before asking after service Problem Possible causes What to do No water comes out Inspection inlet water Pulling out the pipe of inlet water to check if have water flow Low water pressure Add the boost pump Jammed filter...