Dry-Pit installation with submerged pump on legs. 

 

Cables for the pump must be installed in such a way that they avoid any sharp 

bends or getting squeezed. Never let the cables hang in a way that they might get 

sucked into the pump. 

 

The pump is delivered with support legs.  

The pump must be mounted on a solid surface, and the foundation/base must have 

sufficiently strength to support the pump.   

The legs are adjustable; the height is regulated by loosening the two bolts on each 

leg and tighten them again at the desired height. The pump volute is predrilled for 

standard DN flange 

 

Then mount the inlet and discharge pipes. (Suction elbows can be supplied) 

We recommend mounting a ball valve on the suction side, and a ball valve + a non-

return check valve on the discharge side.  

Check that the pipe dimensions are correct according to the required m³/h capacity.  

Contact your local DanPumps A/S dealer, who can advise you. 

 

 

 

Portable installation. 

 

When mounting this installation type, it is very important that the cables are 

installed in such a way that they do not bend, get damaged by vehicles etc.  

It is also important that there is no pulling /towing in the cables or discharge 

hose. 

 

The pump must be mounted on a solid surface and in a vertical position, so it 

does not tip over or “dig” into the sand, sludge etc. 

 

Please note the pump’s inlet is exposed all physical contact must be avoided. 

Keep a minimum safety distance of 5 meters from a pump in operation.  

The pump is capable to give a very powerful suction under water. Never 

underestimate this.  

If necessary, then mount a plate with holes like a strainer, which can be 

screwed onto the pump’s frame to avoid large objects being sucked into the 

pump.  

 

 

Discharge info for all 3 installations. 

 

To reduce load and power dissipation, we recommend use of pipes with the same (DN) or larger diameter 

than the pump discharge. Connection elements that may cause air pockets should not be used under any 

circumstances. 

The diameter of the pipes used, ought to be such, which ensures the water speed remains below 

2 m/s (7 feet per second). 

 

 

7. Electrical installation. 

 

Work is only permitted to be carried out by qualified specialists and must to be carried 

out in accordance with local regulations. Let a qualified electrician do this job. 

Before work commences, ensure that all power is switched off and cannot be switched 

on again. Check that supply voltage and frequency are the same as rated data on the 

pump.  

 

Motors can be used with a power supply deviation of ± 5% voltage and ± 2% frequency, according to 

IEC60034-1  

Connections must be made in such a way as to ensure that a permanently safe electrical connection is 

maintained, both for the main supply and the earth connection. A ground fault circuit breaker is a must. 

 

The electric board must be equipped with a motor guard that fits the motor size.  

This relay must be set as follow for direct or star-delta start: 

 

Summary of Contents for S-WP Series

Page 1: ...End of life the pump must be recycled in accordance with local regulations Version 1 0 2015 English...

Page 2: ...t performance requirements ATEX and FM edition can be offered Fee will be added FM exceptions for some models WARNING If the location has a hazardous media then make sure the pump has been delivered w...

Page 3: ...hased version for either 50 Hz 230 400 V or 400 690 V or 60 Hz 220 V 460 V or 575 1000 V Please see motor label for accurate information for this pump Ambient temperature and media up to max 75 C The...

Page 4: ...allation of a longer cable please contact your local DanPumps A S dealer who can advise you about volt drop and dimensions Also note that cable type and number of cables can vary depending on voltage...

Page 5: ...Pump curves 50 Hz Pump curves 60 Hz...

Page 6: ...value is too low causing damage to the internal elements of the pump Always provide the right suction conditions for the pump Accidents in relation to installation can be minimized by taking special...

Page 7: ...all physical contact must be avoided Keep a minimum safety distance of 5 meters from a pump in operation The pump is capable to give a very powerful suction under water Never underestimate this If ne...

Page 8: ...o jerk The start reaction will be counter clockwise seen from the top of the motor The starting torque can be very powerful even with small pumps Never hold on to the pump and do not start the pump wh...

Page 9: ...lug on top of the cooling jacket water inlet for fast emptying Re plug the water outlet Slowly fill the new cooling liquid into the water inlet on top of the cooling jacket See technical specification...

Page 10: ...d burrs off Push the upper bearing into its position If pressure is needed then put pressure only on the inner ring of the bearing using a piece of pipe and a soft hammer Put the shaft through the sha...

Page 11: ...nd that the cooling pipes are in their right positions Fasten the cooling jacket with four screws Mounting the motor unit in the volute Turn the latch bolts so that the driving unit is free down to th...

Page 12: ...10 Pump data 50Hz 60Hz...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ...12 Pump cutaway...

Page 19: ...13 CE Declaration...

Page 20: ...hird party without the consent of DanPumps If a defect is caused by normal wear and tear inadequate maintenance or faulty repair by unauthorized technician failure to observe the operating instruction...

Reviews: