Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualified electrician.
Make sure the power is isolated from the circuit.
If a four lug metal back box is being used the top and bottom lugs
must be removed.
2. The TLSW 10 (ILM) has two terminal blocks on the reverse, which
should be connected as:
Block 1
L
Live input
SL
Switched Line output
Block 2
Push Button For connection to slave switch(es).†
Must not be connected to the mains.
3. Existing two-way strapper lines can usually be used to connect
these time lag switches in parallel or to connect slave switch(es),
as shown in the wiring diagrams opposite.
4 When these devices are wired in parallel, dependant on the load,
it may not be possible to immediately re-trigger the time lag.
5. The time lag is adjusted via a spindle (see
illustration opposite) by inserting a narrow
(flat) screwdriver through the hole located on
the bottom edge of the device:
Notes:
When wiring has been completed and verified, switch on supply, wait
for 30 seconds* and then test operation.
* If this is not observed, see trouble shooting section for remedy.
† The two terminals on DANLERS slave switches are labelled as:
Plated Slave switches:
Push Button
Grid Slave switches:
L, S
If grid slave switches are used with plated time lag switches, the
L and S terminals must be connected only to the Push Button
terminals on the time lag switch, not to live.
Typical wiring diagrams
1-way TLSW 10 (ILM)
load
L
N
230 VAC
SL
Push
Button
Optional CAPLOAD,
Power factor
correction capacitor.
See minimum load.
L
TLSW 10 (ILM)
TIME
1
min
10
mins
APPROXIMATE
SETTINGS
5 mins
Example of a typical 2-way circuit
load
L
N
230 VAC
Multi-way TLSW 10 (ILM) with slave switches
L
N
230 VAC
load
SL
L
Push button
Slave
Switch
Slave
Switch
TLSW 10
(ILM)
Unused existing wire
terminate safely
Push button
SS 1SL
SS 1SL
Optional CAPLOAD
See minimum load
Multi-way TLSW 10 (ILM) in parallel
L
N
230 VAC
load
SL
L
L
SL
SL
L
Unused existing wire
terminate safely
Push button
Push button
Push button
Optional CAPLOAD(s)
See minimum load
TLSW 10
(ILM)
TLSW 10
(ILM)
TLSW 10
(ILM)