User Manual 

 

USER MANUAL AO 6004 REV B.DOCX

 

3  DCS 6000 Conference System 

3.1 

Features 

DCS 6000 Digital Conference System is a system to be 

used at meetings, where a number of people are 

addressing the ‘Floor’ in a structured manor. The 

audio from the Conference units can be heard in the 

built in loudspeakers in the units. 
The system does also allow for simultaneous 

interpretation for international conferences where 

multiple languages are used. 
To enable all participants to understand the 

proceedings, interpreters can simultaneously 

translate the speaker’s language as required. These 

interpretations are distributed through the connected 

Conference  units and delegates can select the 

language of their choice and listen to it through 

headphones. 
DCS 6000 Digital Conference System comprises of one 

CU 6105 or one CU 6110 Central Unit and a number 

of  Conference  Units,  Gooseneck Microphones  and 

other accessories depending on the system 

configuration. 
The DCS 6000 system  has the following main 

features: 

 

Fully digital 

 

Excellent sound quality  

 

“State of the Art” fully digital integrated 

interpretation, discussion  and voting system 

offering interpretation, language distribution, 

conference microphone and voting facilities with 

attendance check with Chip Card ™. 

 

Digital transmission of audio  from/to  the 

Conference unit to/from the central unit using a 

unique digital DATA and AUDIO bus named DCS-

LAN. 

 

Control  of  up to 4000  conference  units. This 

number does not include Channel Selectors, 

Repeaters etc. In practical use there are no limits 

for the number of Channel Selectors in a system. 

 

Delegate and Interpreter units are powered and 

controlled by the CU 6105 or CU 6110 Central 

Unit.  

 

EX 6010 Extension Unit or PS 6000 Power 

Supplies is available if more units are required. 

 

Delayed switching on of power to the chains, to 

minimize the total ‘in-rush’ current on the Mains 

supply  

 

Designed for 31 interpreted channels and 8 open 

microphones 

 

Audio scrambling of the audio to avoid 

eavesdropping. 

 

Designed in a standard 1HE 19” cabinet. 

 

TCP/IP connection on CU 6105 and CU 6110 for 

external operation of the system using  a PC or 

control system such as AMX ® or Crestron ®. 

 

Functionality on the CU 6105 and CU 6110 

depends on the Feature License uploaded into 

the unit. 

 

Firmware in Delegate units, Interpreter Units, 

Central Units etc. is upgradeable  

 

Operated either stand alone  or from a PC  using 

the CU browser or using SW 6000 software.  

 

Added functionality and comprehensive features 

provided by SW 6000 software package running 

on PC 

The SW 6000 is an optional software package, which 

expands the functionality of the DCS 6000 system. 

The software runs on standard computer technology 

(Standard PC with Windows 7, Server 2008 etc.). 
Main features of the SW 6000 are: 

 

Microphone management  

 

Mimic panel operation 

 

Interpretation management 

 

Voting management 

 

Message handling 

 

Agenda handling 

 

Data stored on SQL data base  

 

Web service interface available for easy links to 

external applications 

 

Multi language user interfaces 

 

Supports different User types with different 

priorities, user interfaces and control 

possibilities 

Summary of Contents for AO 6004

Page 1: ...DCS 6000 User Manual DIS Digital Conference System AO 6004 Audio Output Unit ...

Page 2: ...ser Manual Copyright 2007 DIS USER MANUAL AO 6004 REV B DOCX 10 12 2012 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher ...

Page 3: ...Conference System 5 3 1 Features 5 3 2 System components 6 3 2 1 Interpreter equipment 6 3 2 2 Conference equipment and channel selectors 6 4 Operating instructions 7 4 1 AO 6004 Audio Output Unit 7 4 1 1 General description 7 4 1 2 Features 7 4 1 3 User controls indications connections 8 4 1 4 System settings 8 4 1 5 Normal operation 9 5 System Setup 10 5 1 General guidelines 10 5 2 Typical schem...

Page 4: ...e cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment 2 2 Installation precautions Do not install the unit in a location near heat sources such as radiators or air ducts or in a place exposed to direct sunlight excessive dust or humidity mechanical vibration or shock To avoid moisture condensations do not install the...

Page 5: ...ber does not include Channel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 6105 or CU 6110 Central Unit EX 6010 Extension Unit or PS 6000 Power Supplies is available if more units are required Delayed switching on of power to the chains to minimize the total in rush cu...

Page 6: ... Delegate Dual Delegate or Chairman DC 6120 P Conference Unit portable DC 6190 P Conference Unit portable with two built in channel selectors DM 6680 P Conference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F Conference Unit flush mounted with one built in...

Page 7: ...en out of the possible 31 digital channels as well as the Floor channel in 3 qualities The 4 decoded channels are available on 4 analog outputs XLR connectors transformer balanced A number of AO 6004 can be combined to decode more channels Up to 20 pieces AO 6004 can be connected and configured in one system to decode more channels Easy to use with preconfigured settings and automatic channel assi...

Page 8: ... Pre configured settings 4 1 4 1 The AO 6004 comes with pre configured settings and can be used without additional configurations The AO 6004 automatically assigns channels to the outputs at start up Output A is assigned channel 0 Floor Output B is assigned channel 1 Output C is assigned channel 2 and Output D is assigned channel 3 The output volume for each channel is 3 dB which is the recommende...

Page 9: ...to the appropriate units tape recorders infrared transmitters etc Switch on the power on the Central Unit During the initialization the AO unit will automatically assign channels to the outputs The unit is immediately ready to use after start up unless other channels need to be assigned to the outputs or the channel volume needs to be adjusted These adjustments can only be done using the SW 6000 ...

Page 10: ... cables between the units The max usable cable length depends on the units connected and length of feeding cables etc Maximum cable length in one chain when using repeaters is 650 m 5 2 Typical schematics Connect the AO 6004 to the DCS 6000 network using Cat 5 cables The Analog Audio output connectors are connected to either tape recorders for recording the interpreted channels or to a DT 6008 Inf...

Page 11: ...er the audio output level on the AO 6004 has to be set to match the sensitivity on the transmitter The correct level on each connected channel on the AO 6004 is 3dB This level is factory preset but can as earlier mentioned be changed using SW 6000 Please refer to the section Pre configured settings on page 8 The DT 60XX input level settings should be set to 6dB ...

Page 12: ...trol commands in out By using SW 6000 the user can control the following settings in the AO 6004 through the CU 6105 CU6110 Channel number for each output channel Volume setting for each channel The settings can only be read or controlled from the SW 6000 Specifications are subject to change without notice 6 2 Connection Details DCS LAN Chain The DCS 6000 system uses Cat5e Cat6 or Cat7 F UTP or U ...

Page 13: ... for feeding cables terminating in wall outlets or patch panels Analog Audio Out XLR3 male Pin Signal Cable type 1 Earth 2 x 0 25 mm2 shielded 2 Signal 3 Signal 6 3 Accessories Cat5e Connection Cables AWG24 EC 6001 0 5 Connection Cable 0 5 m 10 03 22500 EC 6001 01 Connection Cable 1 m 10 03 23101 EC 6001 02 Connection Cable 2 m 10 03 23201 EC 6001 05 Connection Cable 5 m 10 03 23501 EC 6001 10 Con...

Reviews: