Danish Interpretation Systems
Appendix
Manual 01 18 04467
44
Appendix
Technical appendix
Cabling
CAT5e
The DCS 6000 system uses CAT5e or CAT6 FTP
or STP cables with screened RJ45 connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
How to wire a CAT5e (EIA 568-B) Cable:
Pin Function
Connector #1 Connector #2
1
In-going +
ORG/WHT
ORG/WHT
2
In-going -
ORG
ORG
3
+48V
WHT/GRN
WHT/GRN
4
0V
BLU
BLU
5
0V
BLU/WHT
BLU/WHT
6
+48V
GRN
GRN
7
Outgoing -
BRN/WHT
BRN/WHT
8
Ou BRN
BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Pair 1:
Pin 1 & 2
Pair 2:
Pin 3 & 6
Pair 3:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring specifications as stated in CAT5e (EIA 568-
B) have to be followed.
HD15 connector
The HD15 connector on the MU 6040 D/C and MU
6042 has the following PIN layout:
Pin
Signal
Cable type
1
- Loudspeaker output
2
Speak 1 LED
3
Request 1 LED
4
ON/OFF 1 button input
5
Delegate OFF button /
*ON/OFF 2 button input
6
Optional input
7
+ Loudspeaker output
(8 ohm)
8
NC
9
*Speak 2 LED
10 + lamp
11 +5V
12 0V
13 MIC ground
14 + MIC
15
*Request 2 LED
DIS type:
#2029
or according to
the specific
installation.
* Only connected on MU 6042
Connection of GM 652x to AM/MU 6040
AM/MU 6040 – HD 15
GM 652x – XLR 3P
Pin Comments
Pin
Comments
10 + lamp
4
House
12 0V
3
13 MIC ground
1
14 + MIC
2