MAINTENANCE

ALUMINIUM GREASE FILTERS

The grease filters should be cleaned frequently. Approx. every 2 months of operation, 

or more frequently for heave use. 
• 

Use warm water and dishwashing liquid to clean.

• 

Ensure they are completely dry before re-installing and using.

• 

Not recommended for cleaning dishwasher.

• 

Avoid caustic or powerful cleaning solutions.

LAMPS

This range hood requires 2 LED lamps (2W each).
NOTE: LIGHT BULBS/LAMPS ARE NOT COVERED UNDER THE 24-MONTH WARRANTY.

CAUTION WITH INSTALLATION

• 

To reduce the risk of fire, the use of metal duct work is preferred.

• 

Do not use flammable material to convey exhaust air.

• 

Decide where the duct work will run between the hood and the outside.

• 

A straight and short duct run will allow the hood to perform most efficiently.

• 

Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of 

them as possible. Larger ducting may be required for best performance with longer duct runs.

• 

Attach an adequate length of 125mm round duct to the air outlet adapter.

• 

The air must not be discharged into a flue that is used for exhausting fume from appliances 

burning gas or other fuels. Regulations concerning the discharge of air have to be followed. 

Check with the local authority and building codes for exhaust ducting requirements.

• 

Install a roof/wall cap. Connect round metal ductwork to cap and work back towards 

hood location.

FITTING UNDER WALL UNIT

1. 

Before fixing the hood to the wall unit, drill a hole of 130mm diameter in the wall unit.

2. 

In any case, check the position of the power outlet and consider where the power cable 

will run, since the hole might have to be made in the wall unit to accommodate it.

3. 

Drill 4 holes into the wall unit, respecting the distance indicated. Push the hood up against 

the wall unit and insert the 4 screws operating from inside the wall unit.

4. 

Make the electrical connection.

Summary of Contents for DAN6SO

Page 1: ...A p p l i a n c e U s e r M a n u a l 60CM DUCTED SLIDEOUT RANGEHOOD DAN6SO danielaappliances com au ...

Page 2: ...with her father for many years learning from his decades of industry experience Daniela with her extensive knowledge and understanding of appliances now continues her father s legacy with a modern flare Our products are extensively tested and come with ISO certification certificates prior to importation Daniela Appliances continuously designs and sources the best parts to bring you an elegant feel...

Page 3: ...ances com au PAGE 3 DAN6SO 60CM DUCTED SLIDEOUT RANGEHOOD MODEL DAN6SO Venting Type Ducting Rated Voltage 230V Rated Power Frequency 50Hz Light Power 2 X 2W Motor Power 2 X 120W Total Power 244W Motor 2 Diameter of Outlet Adapter 120mm Dimension mm W598 x D488 x H176 ...

Page 4: ...exhaust gas The kitchen must have an opening directly with the open air in order to guarantee the entry of clean air The minimum distance is 750mm from the range hood to a gas hob and is 650mm to an electric hob If the installation instructions for gas hobs specify a greater distance this must be taken into account SAVE THIS INSTRUCTION IN A SAFE PLACE FOR FUTURE REFERENCE Thank you for choosing D...

Page 5: ...FAILURE IN DOING SO CAN CAUSE PHYSICAL HARM OR INJURIES The range hood has been designed only for domestic use to eliminate kitchen fumes Never use the hood for purposes other than what it has been designed for Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the pan side...

Page 6: ...é under the range hood The exhaust air must not be discharged into a flue which is used for exhausting fumes from appliances burning gas or other fuels ELECTRICAL SHOCK HAZARD AND FIRE TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards...

Page 7: ... possible on the inside It is advisable to avoid any drastic changes in duct cross section recommended diameter 125mm Decide on the position of the hole for the air outlet The hole must be in the ceiling according to your requirements but must be in vertical line with your hood Bear in mind that the hood can expel air through the top air outlet only INSTALLATION OF ELECTRICAL The electrical wiring...

Page 8: ...ansitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with longer duct runs Attach an adequate length of 125mm round duct to the air outlet adapter The air must not be discharged into a flue that is used for exhausting fume from appliances burning gas or other fuels Regulations concerning the discharge of air have to be...

Page 9: ...luminum filters Aluminum filters saturated Replace the aluminum filters with new sets Whirring sound Foreign object in contact with fan blade Contact technician When you unpack the appliance make sure that it has not been damaged in any way If you have any doubts at all DO NOT INSTALL OR USE THE APPLIANCE In this instance please contact your retailer or Daniela Appliances direct Keep packing mater...

Page 10: ...ase record their details below for future reference TECHNICAN TRADESMAN WHO INSTALLED LICENSE NUMBER DATE OF INSTALLATION INSTALLATION RECEIPT NUMBER If you require more information service warranty or spare parts enquiries please contact customer care DANIELA APPLIANCES PTY LTD 02 9604 1226 9am 5pm EST Monday Friday NOTE Model number and details are to be recorded below for future reference Pleas...

Page 11: ...turned with in 30 days of the invoice date for a full refund A collection fee of 50 will be charged should you require Daniela Appliances Pty Ltd to collect the stock If your goods have been unboxed but otherwise are in as new condition Have not been used or connected a 20 restocking fee 20 of the purchase price will apply Daniela Appliances Pty Ltd DOES NOT DEAL WITH FACTORY SECONDS DAMAGES OR OP...