CAN / Power connector
5-pin M12, male, A-coded, front view
5
2
1
4
3
kwa1459396274675
Connect the device to the CANbus and the power to supply voltage (DC battery or instrumental power
supply).
CAN connector J-1 (left side—top view)
Pin
Designation
Color
Description
1
Ground
Brown
Power supply
2
8 to 32 VDC
White
Power supply
3
*
Terminal 15
Blue
Ignition
4
CAN high
Black
CANbus
5
CAN low
Gray
CANbus
*
Pin 3, Terminal 15, if not used for controlling the power management, must be connected to VCC.
RS-232 connector
5-pin M12, male, A-coded, front view
5
2
1
4
3
kwa1459396274675
Connect the device to the PC via the RS-232 port.
RS-232 connector J-2 (right side—top view)
Pin
Designation
Color
Description
1
Ground
Brown
Power supply
2
—
White
—
3
BOOT (DSR)
Blue
Boot pin, RS-232 Data Set Ready (input)
*
4
RXD RS-232h
Black
Receive (input)
5
TXD RS-232
Gray/Green Transmit (output)
*
PIN3 is used only to activate the boot mode. To activate the boot mode PIN3 is connected to the DTR pin of the
RS-232 interface of the PC. The software controls this signal automatically. In normal operation, this pin must not be
connected.
Technical Information
WS103 Remote Solution
Installation
24 |
©
Danfoss | April 2016
BC00000365en-US0102
Summary of Contents for WS103
Page 29: ...Technical Information WS103 Remote Solution Danfoss April 2016 BC00000365en US0102 29...
Page 30: ...Technical Information WS103 Remote Solution 30 Danfoss April 2016 BC00000365en US0102...
Page 31: ...Technical Information WS103 Remote Solution Danfoss April 2016 BC00000365en US0102 31...