6.4.3 Oil Volume
The recommended oil quantity for the particular mounting
position is indicated on the motor nameplate. When filling,
ensure that the upper gear unit components are also well
lubricated.
130BB890.14
P1
P2
P3
Figure 6.2 Mounting Positions
Mounting position
P1
1)
P2
P3
Oil volume for
OneGearDrive
74.4 fl oz
[2.2 l]
105 fl oz
[3.1 l]
Table 6.5 Oil Volume in Fluid Ounces
1) P1 is no longer available in the Danfoss DRIVECAT configurator.
Use P2 also for P1 installations.
•
32 fl oz = 1 US Quart
•
128 fl oz = 1 US Gallon
6.4.4 Changing the Oil
CAUTION
DANGER OF BURNS
The surface of the OneGearDrive and the oil in the
OneGearDrive can reach high temperatures during
operation.
•
Do not touch the OneGearDrive until it has
cooled down.
•
Do not carry out an oil change until the oil has
cooled down sufficiently.
1
2
130BC424.10
Figure 6.3 OneGearDrive Oil Screws 1 and 2
Draining the oil
1.
Once the OneGearDrive and the oil have cooled
down, remove the OneGearDrive from your
system.
2.
Bring the OneGearDrive into a vertical position
and remove oil screws (1) and (2).
3.
Turn the OneGearDrive into a horizontal position
and drain the oil through screw hole 1 into a
suitable container.
4.
Turn the OneGearDrive back into a vertical
position.
Filling the oil
1.
Fill the OneGearDrive with the appropriate
amount of oil through screw hole (1).
2.
Remove all traces of oil from the surface of the
OneGearDrive using a soft cloth.
3.
Re-insert and tighten oil screws (1) and (2).
NOTICE!
The required oil quantities can be found on the
nameplate and in
NOTICE!
The original Danfoss stainless steel oil screws can be
reused. They do not require any additional seal.
NOTICE!
The OneGearDrive does not require any breather vents.
Never install a breather vent instead of the oil screws.
6.5 Spare Parts
Spare parts can be ordered via the Danfoss VLT Shop: