6.2.4 Characteristic Data
Definition
Value and unit
Input
Input voltage
400–480 V
±
10%
Efficiency
98.5% at 400 V
Input current
12.5 A continuous
20 A intermittent
Output
Output voltage
ISD Line 1: UDC 1 & ISD Line 2: UDC 2
565–679 V
±
10%
2)
Output voltage
ISD Line 1: STO 1 & ISD Line 2: STO 2
24 V
±
10%
Output voltage
ISD Line 1: AUX 1 & ISD Line 2: AUX 2
24–48 V
±
10%
Output current
ISD Line 1: AUX 1 & ISD Line 2: AUX 2
15 A
1)
Output current UDC
15 A
1)
Output current
ISD Line 1: STO 1 & ISD Line 2: STO 2
1 A
1)
Output power
8 kW at 400 V
9.7 kW at 480 V
Housing
Dimensions (W x H x D)
130 x 268 x 80 mm
Weight
8.3 kg
Table 6.25 Servo Access Box Characteristic Data
1) Depends on the number of servo drives connected in the
application. The current per servo drive is 6.7 mA.
6.2.5 General Specifications and
Environmental Considerations
Protection rating
IP20 (UL rating: Open type)
Vibration test
Random vibration: 1.14 g (2h/axis
according to EN 60068-2-64)
Sinusoidal vibration: 0.7 g (2h/axis
according to EN 60068-2-6)
Maximum relative
humidity
Storage/transport and stationary use:
5–93% (non-condensing)
Ambient
temperature range
5–50
°
C operating temperature
(24-hour average maximum 45
°
C)
Transport: -25 to +70
°
C
Storage: -25 to +55
°
C
Installation elevation Maximum 1000 m above sea level
EMC standard for
emission and
immunity
EN 61800-3
Table 6.26 General Specifications and Environmental Conditions
SAB
6.2.6 Mains Supply
Refer to
for information on the
mains supply for the SAB.
6.2.7 Derating
The cooling capability is decreased at lower air pressure.
Below 1000 m altitude no derating is necessary. Above
1000 m, the ambient temperature or the maximum output
current has to be derated.
Maximum
I
out
(%)
a t T
A MB , M A X
Altitude (km)
T
a t 100% I
out
D
100%
91%
82%
0 K
–5 K
–9 K
1 k m
2 k m
3 k m
130BF796.10
A MB , M A X
(K )
Illustration 6.32 Derating SAB
6.2.8 Connection Tightening Torques
Decoupling plate screws: 2 Nm
Specifications
Design Guide
MG36C102
Danfoss A/S © 08/2017 All rights reserved.
73
6
6