NOTE
In motors without phase insulation paper or other
insulation reinforcement suitable for operation with
voltage supply (such as a frequency converter), fit a Sine-
wave filter on the output of the frequency converter.
4
130BC981.10
1
2
2
2
2
3
3
2
2
2
2
6
6
7
4
5
Illustration 3.8 Cable Entry Holes - Large Unit
1
Brake M20
2
8xM16
3
2xM20
4
Mains cables M25
5
M20
6
24 V M20
7
Motor M25
Table 3.5 Legend
3.3.2 Mains Disconnectors
The frequency converter is available with optional
•
service switch on mains side or motor side
•
built-in circuit breaker on the mains side (large
unit only)
Specify the requirement when ordering.
and
show examples of
configuration for the large unit.
130BC986.10
Illustration 3.9 Location of Service Switch, Mains Side, Large Unit,
(IP66/Type 4X indoor)
System Integration
VLT
®
Decentral Drive FCD 302
32