4.1.6 4-** Limits/Warnings
Par. No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
4-1* Motor Limits
4-10
Motor Speed Direction
[0] Clockwise
All set-ups
FALSE
-
Uint8
4-11
Motor Speed Low Limit [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-12
Motor Speed Low Limit [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-13
Motor Speed High Limit [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-14
Motor Speed High Limit [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-16
Torque Limit Motor Mode
110 %
All set-ups
TRUE
-1
Uint16
4-17
Torque Limit Generator Mode
100 %
All set-ups
TRUE
-1
Uint16
4-18
Current Limit
ExpressionLimit
All set-ups
TRUE
-1
Uint32
4-19
Max Output Frequency
ExpressionLimit
All set-ups
FALSE
-1
Uint16
4-5* Adj. Warnings
4-50
Warning Current Low
0 A
All set-ups
TRUE
-2
Uint32
4-51
Warning Current High
ImaxVLT (P1637)
All set-ups
TRUE
-2
Uint32
4-52
Warning Speed Low
0 RPM
All set-ups
TRUE
67
Uint16
4-53
Warning Speed High
outputSpeedHighLimit
(P413)
All set-ups
TRUE
67
Uint16
4-54
Warning Reference Low
-999999 N/A
All set-ups
TRUE
-3
Int32
4-55
Warning Reference High
999999 N/A
All set-ups
TRUE
-3
Int32
4-56
Warning Feedback Low
-999999 ReferenceFeed-
backUnit
All set-ups
TRUE
-3
Int32
4-57
Warning Feedback High
999999 ReferenceFeed-
backUnit
All set-ups
TRUE
-3
Int32
4-58
Missing Motor Phase Function
ExpressionLimit
All set-ups
TRUE
-
Uint8
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-61
Bypass Speed From [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-62
Bypass Speed To [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-63
Bypass Speed To [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-64
Semi-Auto Bypass Set-up
[0] Off
All set-ups
FALSE
-
Uint8
Table 4.7
4.1.7 5-** Digital In/Out
Par. No. # Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
5-0* Digital I/O mode
5-00
Digital I/O Mode
[0] PNP - Active at 24V
All set-ups
FALSE
-
Uint8
5-01
Terminal 27 Mode
[0] Input
All set-ups
TRUE
-
Uint8
5-02
Terminal 29 Mode
[0] Input
All set-ups
TRUE
-
Uint8
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-11
Terminal 19 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-12
Terminal 27 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-13
Terminal 29 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-14
Terminal 32 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-15
Terminal 33 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-16
Terminal X30/2 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
172
MG16H102 - VLT
®
is a registered Danfoss trademark
4
4