4.2.2 1-10 to 1-12 Motor Selection
NOTICE
This parameter group cannot be adjusted while the
motor runs.
The following parameters are active (x) depending on the
setting of
parameter 1-10 Motor Construction
.
Parameter 1-10 Motor Construction
[0]
Asynchron
[1] PM
Motor
non-
salient
Parameter 1-00 Configuration Mode
x
x
Parameter 1-03 Torque Characteristics
x
Parameter 1-06 Clockwise Direction
x
x
Parameter 1-14 Damping Gain
x
Parameter 1-15 Low Speed Filter Time
Const.
x
Parameter 1-16 High Speed Filter Time
Const.
x
Parameter 1-17 Voltage filter time const.
x
Parameter 1-20 Motor Power [kW]
x
Parameter 1-22 Motor Voltage
x
Parameter 1-23 Motor Frequency
x
x
Parameter 1-24 Motor Current
x
x
Parameter 1-25 Motor Nominal Speed
x
x
Parameter 1-26 Motor Cont. Rated Torque
x
Parameter 1-29 Automatic Motor
Adaption (AMA)
x
x
Parameter 1-30 Stator Resistance (Rs)
x
x
Parameter 1-33 Stator Leakage Reactance
(X1)
x
Parameter 1-35 Main Reactance (Xh)
x
Parameter 1-37 d-axis Inductance (Ld)
x
Parameter 1-39 Motor Poles
x
x
Parameter 1-40 Back EMF at 1000 RPM
x
Parameter 1-52 Min Speed Normal
Magnetising [Hz]
x
Parameter 1-60 Low Speed Load Compen-
sation
x
Parameter 1-61 High Speed Load
Compensation
x
Parameter 1-62 Slip Compensation
x
Parameter 1-63 Slip Compensation Time
Constant
x
Parameter 1-64 Resonance Dampening
x
Parameter 1-65 Resonance Dampening
Time Constant
x
Parameter 1-66 Min. Current at Low
Speed
x
Parameter 1-71 Start Delay
x
x
Parameter 1-72 Start Function
x
x
Parameter 1-73 Flying Start
x
x
Parameter 1-80 Function at Stop
x
x
Parameter 1-82 Min Speed for Function at
Stop [Hz]
x
x
Parameter 1-90 Motor Thermal Protection
x
x
Parameter 2-00 DC Hold Current
x
Parameter 2-01 DC Brake Current
x
Parameter 2-02 DC Braking Time
x
Parameter 2-04 DC Brake Cut In Speed
[Hz]
x
Parameter 2-06 Parking Current
x
x
Parameter 2-10 Brake Function
x
x
Parameter 2-16 AC brake Max. Current
x
Parameter 2-17 Over-voltage Control
x
x
Parameter 4-10 Motor Speed Direction
x
x
Parameter 4-12 Motor Speed Low Limit
[Hz]
x
x
Parameter 4-14 Motor Speed High Limit
[Hz]
x
x
Parameter 4-18 Current Limit
x
x
Parameter 4-19 Max Output Frequency
x
x
Parameter 4-58 Missing Motor Phase
Function
x
x
Parameter 14-40 VT Level
x
Parameter 14-41 AEO Minimum Magneti-
sation
x
Parameter 30-22 Locked Rotor Detection
x
Parameter 30-23 Locked Rotor Detection
Time [s]
x
Table 4.2 Parameters Activated by Setting of
Parameter 1-10 Motor Construction
1-10 Motor Construction
Option:
Function:
[0]
*
Asynchron
For asynchronous motors.
[1]
PM, non salient
SPM, non Sat
For permanent magnet (PM) motors with
surface-mounted (non-salient) magnets.
Refer to
parameter 1-14 Damping Gain
to
parameter 1-17 Voltage filter time const.
for
details about optimizing the motor
operation.
[2]
PM, salient IPM,
non Sat
For permanent magnet (PM) motors with
interior (salient) magnets, without
inductance saturation control.
[3]
PM, salient IPM,
Sat
For permanent magnet (PM) motors with
interior (salient) magnets, with inductance
saturation control.
1-11 Motor Selection
Option:
Function:
[0]
*
Default Motor Selection Automatically sets the manufac-
turer's settings for the selected
motor.
Parameters
Programming Guide
MG03N202