background image

1.6  Symbols, Abbreviations and

Conventions

Abbreviation

Definition

ACK

Acknowledge

BOC

Bus off counter

BOOL

Boolean expression

CAN

Controller area network

CSMA/CA

Carrier sense multiple access/collision avoidance

COS

Change of state

CTW

Control word

EDS

Electronic data sheet

EMC

Electromagnetic compatibility

ETR

Electronic thermal relay

FIFO

First In first out

HF

High frequency

HPFB

High performance field bus

I/O

Input/output

ISO

International standards organization

LCD

Liquid crystal display

LED 

Light emitting diode

LSB

Least significant bit

MAC ID

Media access control identifier

MAV

Main actual value

MRV

Main reference value

MSB

Most significant bit

N/A

Not applicable

ODVA

Open deviceNet vendor association

OSI

Open systems interconnection

PC

Personal computer

PCD

Process data

PIW

Peripheral input word

PLC

Programmable logic control

PNU

Parameter number

PPO

Parameter-process data object

QW

Peripheral output word

SINT

Signed integer

STW

Status word

VSD

Variable speed drive

UDINT

Unsigned double integer

UNIT

Unsigned integer

USINT

Unsigned short integer

Table 1.1 Symbols and Abbreviations

Conventions

Numbered lists indicate procedures.
Bullet lists indicate other information and description of
illustrations.
Italicised text indicates:

Cross reference

Link

Parameter name

Introduction

Installation Guide

MG33D502

Danfoss A/S © Rev. 03/2015 All rights reserved.

3

1

1

Summary of Contents for VLT DeviceNet MCA 104

Page 1: ...MAKING MODERN LIVING POSSIBLE Installation Guide VLT DeviceNet MCA 104 VLT Frequency Converter Series FC 102 FC 202 FC 301 FC 302 vlt drives danfoss com...

Page 2: ......

Page 3: ...n 6 3 1 Safety Instructions 6 3 2 EMC compliant Installation 6 3 3 Grounding 6 3 4 Cable Routing 6 3 5 Mounting 7 3 6 Setting Address Switches 8 3 7 Electrical Installation 8 3 8 Reassembling Cover 11...

Page 4: ...tions and manuals are available from Danfoss See www danfoss com BusinessAreas DrivesSo lutions Documentations VLT Technical Documentation htm for listings 1 3 Product Overview 1 3 1 Intended Use This...

Page 5: ...AV Main actual value MRV Main reference value MSB Most significant bit N A Not applicable ODVA Open deviceNet vendor association OSI Open systems interconnection PC Personal computer PCD Process data...

Page 6: ...ing the motor may start at any time Unintended start during programming service or repair work can result in death serious injury or property damage The motor can start with an external switch a field...

Page 7: ...trical work conforms to national and local electrical codes Follow the procedures in this manual CAUTION INTERNAL FAILURE HAZARD An internal failure in the frequency converter can result in serious in...

Page 8: ...s as short as possible Establish electrical contact between the cable screen and the frequency converter enclosure by using metal cable glands or by using the clamps provided on the equipment Use high...

Page 9: ...3 3 or with the connector facing down for bottom cable entry see Illustration 3 4 If an MCB option is installed only top cable entry is possible 5 Remove the knock out plate from the new LCP cradle 6...

Page 10: ...ameter 10 02 MAC ID ensure that all address switches are set to ON When the address is already set using address hardware switches the address value shown in parameter 10 02 MAC ID is read only Illust...

Page 11: ...tripped cable between the spring loaded metal clamps to establish mechanical fixation and electrical contact between cable screen and ground 130BD877 10 1 2 1 Cable screen 2 EMC bracket Used for top c...

Page 12: ...us connector on the fieldbus option terminal V CAN_L Drain CAN_H V 3 Prepare the fieldbus cable by stripping a section of the cable insulation Keep the unshielded wire as short as possible For cable s...

Page 13: ...side the unit see Illustration 3 12 130BC527 10 Illustration 3 12 Wiring for Enclosure Types D E and F 3 8 Reassembling Cover 1 Mount the new front cover and the LCP 2 Attach the sticker with the corr...

Page 14: ...2 bi colour LEDs on the DeviceNet card indicate the status of DeviceNet communication The lower LED NS indicates the net status The upper LED MS indicates the module status MS Upper left LED NS Lower...

Page 15: ...itical link failure Red Table 4 2 LED Network Status NS 4 2 2 No Communication with the Frequency Converter When there is no communication with the frequency converter proceed with the following check...

Page 16: ...lation 8 Electrical interference 6 EMC interference 6 EMC compliant installation 6 Exploded view 7 G Grounding 6 H High voltage 4 I Intended use 2 Items supplied 2 L Leakage current 4 LED 3 LED panel...

Page 17: ...Index Installation Guide MG33D502 Danfoss A S Rev 03 2015 All rights reserved 15...

Page 18: ...ts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respec...

Reviews: