15-61 Option SW Version
Array [8]
Range:
Function:
0
*
[0 - 20 ]
View the installed option software version.
15-62 Option Ordering No
Array [8]
Range:
Function:
0
*
[0 - 8 ] Shows the ordering number for the installed
options.
15-63 Option Serial No
Array [8]
Range:
Function:
0
*
[0 - 18 ]
View the installed option serial number.
15-70 Option in Slot A
Range:
Function:
0
*
[0 - 30 ] View the type code string for the option installed
in slot A and a translation of the type code string.
For example, for type code string
AX
, the
translation is
No option
.
15-71 Slot A Option SW Version
Range:
Function:
0
*
[0 - 20 ] View the software version for the option installed
in slot A.
15-72 Option in Slot B
Range:
Function:
0
*
[0 - 30 ] View the type code string for the option installed
in slot B and a translation of the type code string.
For example, for type code string
BX
, the
translation is
No option
.
15-73 Slot B Option SW Version
Range:
Function:
0
*
[0 - 20 ] View the software version for the option installed
in slot B.
15-74 Option in Slot C0/E0
Range:
Function:
0
*
[0 - 30 ] View the type code string for the option installed
in slot C and a translation of the type code string.
For example, for type code string
CXXXX
, the
translation is
No option
.
15-75 Slot C0/E0 Option SW Version
Range:
Function:
0
*
[0 - 20 ] View the software version for the option installed
in slot C.
15-76 Option in Slot C1/E1
Range:
Function:
0
*
[0 - 30 ] Shows the type code string for the option in slot
C1 (CXXXX if no option) and the translation, that
is
No option
.
15-77 Slot C1/E1 Option SW Version
Range:
Function:
0
*
[0 - 20 ] Shows the software version for the installed
option in option slot C.
15-80 Fan Running Hours
Range:
Function:
0 h
*
[0 - 2147483647
h]
View how many hours the heat sink
fan has run (increments for every
hour). The value is saved when the
frequency converter is turned off.
15-81 Preset Fan Running Hours
Range:
Function:
0 h
*
[0 - 99999 h] Enter the preset fan running hours counter,
see
parameter 15-80 Fan Running Hours
This parameter cannot be selected via the
serial port, RS485.
15-89 Configuration Change Counter
Range:
Function:
0
*
[0 - 65535 ]
NOTICE
This parameter cannot be adjusted while
the motor is running.
3.15.11 15-9* Parameter Info
15-92 Defined Parameters
Range:
Function:
0
*
[0 - 9999 ] View a list of all defined parameters in the
frequency converter. The list ends with 0.
15-93 Modified Parameters
Range:
Function:
0
*
[0 - 9999 ] View a list of the parameters that have been
changed from their default setting. The list ends
with 0. Changes may not be visible until up to
30 s after implementation.
15-98 Drive Identification
Range:
Function:
0
*
[0 - 40 ] This parameter contains data used by the MCT 10
Set-up Software.
Parameter Descriptions
VLT
®
AutomationDrive FC 301/302
208
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
3
3
Summary of Contents for VLT AutomationDrive FC 302