5-60 Terminal 27 Pulse Output Variable
Option:
Function:
[102] Feedback
[103] Motor Current
[104] Torque rel to limit
[105] Torq relate to rated
[106] Power
[107] Speed
[108] Torque
[109] Max Out Freq
[119] Torque % lim
5-62 Pulse Output Max Freq #27
Range:
Function:
Size
related
*
[0 - 110000
Hz]
Set the maximum frequency for
terminal 27 corresponding to the
output variable selected in
parameter 5-60 Terminal 27 Pulse
Output Variable
.
5-63 Terminal 29 Pulse Output Variable
Option:
Function:
NOTICE
This parameter is available for FC
302 only.
[0]
No operation
Select the display output for terminal
29.
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[51]
MCO controlled
[97]
Reference After
Ramp
NOTICE
This option is available only with
software version 48.XX.
Actual speed reference after the ramp.
Use this output as master signal for
speed synchronization of follower
frequency converters. The reference is
set in
parameter 16-48 Speed Ref. After
[99]
Virtual Master
Speed
NOTICE
This option is available only with
software version 48.XX.
Virtual master signal for controlling
the speed or position of the followers.
[100] Output frequency
[101] Reference
[102] Feedback
[103] Motor Current
[104] Torque rel to limit
5-63 Terminal 29 Pulse Output Variable
Option:
Function:
[105] Torq relate to
rated
[106] Power
[107] Speed
[108] Torque
[109] Max Out Freq
[119] Torque % lim
5-65 Pulse Output Max Freq #29
Range:
Function:
Size
related
*
[0 - 110000
Hz]
Set the maximum frequency for
terminal 29 corresponding to the
output variable set in
parameter 5-63 Terminal 29 Pulse
Output Variable
5-66 Terminal X30/6 Pulse Output Variable
Select the variable for readout on terminal X30/6.
This parameter is active when VLT
®
General Purpose I/O MCB 101
is installed in the frequency converter.
Same options and functions as
parameter group 5-6* Pulse
Outputs
.
Option:
Function:
[0]
No operation
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[51]
MCO controlled
[97]
Reference After
Ramp
NOTICE
This option is available only
with software version 48.XX.
Actual speed reference after the
ramp. Use this output as master
signal for speed synchronization of
follower frequency converters. The
reference is set in
parameter 16-48 Speed Ref. After
Ramp [RPM]
.
[99]
Virtual Master Speed
NOTICE
This option is available only
with software version 48.XX.
Virtual master signal for controlling
the speed or position of the
followers.
[100] Output frequency
[101] Reference
[102] Feedback
[103] Motor Current
[104] Torque rel to limit
[105] Torq relate to rated
[106] Power
Parameter Descriptions
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
131
3
3