VLT® 5000 Crane
Name (index 6):
The Name returns a string value in ASCII format,
containing the name of the parameter.
Example:
In this example the master reads the name of
parameter 001,
Language
.
The following telegram must be sent to the
frequency converter:
STX
LGE
ADR
PKE
IND
PWE
HIGH
PWE
LOW
PCD1
PCD2
BCC
02
0E
01
40 01
00 06
00 00
00 00
XX XX
XX XX
XX
STX =
02 Start byte
LGE =
0E Length of remaining telegram
ADR =
Sends the frequency converter on
Address 1, Danfoss format
PKE =
4001; 4 in the PKE field indicates
a
Read Parameter Description
and
01 indicates parameter number
001,
Language
IND =
0006; 6 indicates that
Names
is
required.
The response from the frequency converter will be:
STX
LGE
ADR
PKE
IND
PVA
PCD1
PCD2
BCC
02
12
01
30 01
00 06
4C41 4E47 5541
4745
XXXX
XXXX
XX
PKE =
3001; 3 are the response for
Name
and 01 indicates the parameter
number 001,
Language
IND =
00 06; 06 indicates that
Name
is
sent.
PVA =
4C 41 4E 47 55 41 47 45
L A N G U A G E
The parameter value channel is now set up to a
visible string which returns an ASCII character for
each letter in the parameter name.
MG.50.N4.02 - VLT is a registered Danfoss trademark
108