•
•
•
•
•
10.463 (ID 1239) Inching Reference 1
Location in the menu:
P2.4.15
(Multi-purpose Control Application)
Use this parameter to set the frequency references for the inching function.
10.464 (ID 1240) Inching Reference 2
Location in the menu:
P2.4.16
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the frequency references for the inching function.
10.465 (ID 1241) Speed Share
Location in the menu:
P2.11.5
(Multi-purpose Control Application)
Use this parameter to set extra scaling to the frequency reference.
Defines the percentage for final speed reference from received speed reference.
10.466 (ID 1244) Torque Reference Filter Time
Location in the menu:
P2.10.12
(Multi-purpose Control Application)
Use this parameter to set the filtering time for the final torque reference.
10.467 (ID 1248) Load Share
Location in the menu:
P2.11.6
(Multi-purpose Control Application)
Use this parameter to set extra scaling to the torque reference.
Defines the percentage for final torque reference from received torque reference.
10.468 (ID 1250) Flux Reference
Location in the menu:
P2.6.15.32
(Multi-purpose Control Application)
Use this parameter to set scaling to the magnetizing current of the motor.
10.469 (ID 1252) Speed Step
Location in the menu:
P2.6.15.1
(Standard Application, Local/Remote Control Application, Multi-step Speed Control Application, PID Control Applica-
tion
P2.6.18.23
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.25
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to adjust the speed controller when VACON
®
NCDrive is used.
See closer VACON
®
NCDrive Tools: Step response. Use this tool to give a step value to speed reference after ramp control.
10.470 (ID 1253) Torque Step
Location in the menu:
P2.6.18.24
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.26
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to adjust the torque controller when VACON
®
NCDrive is used.
See closer VACON
®
NCDrive Tools: Step response. Use this tool to give step to torque reference.
10.471 (ID 1257) Inching Ramp
Location in the menu:
P2.4.17
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the ramp time when inching is active.
10.472 (ID 1262) Overvoltage Reference Selection
Location in the menu:
P2.4.23
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the overvoltage reference selection.
This parameter defines overvoltage reference level. Overvoltage reference level depending on the status of the brake chopper.
AB296635287482en-000301 / DPD00903
284 | Danfoss A/S © 2023.02
Parameter Descriptions
VACON® NX All-in-One
Application Guide
Summary of Contents for VACON NX
Page 1: ...Application Guide VACON NX All in One drives danfoss com...
Page 2: ......