This monitoring value shows the current unbalance when condition-based monitoring is activated. For stator winding, the monitor-
ing motor currents are being evaluated to find evolving unbalances. For this purpose, the current unbalance is computed and moni-
tored.
9.130 (ID 3618) Voltage Unbalance
Location in the menu:
V1.24.2.6
(Multi-Purpose Control Application in VACON
®
NXP only)
This monitoring value shows the voltage unbalance when condition-based monitoring is activated. For stator winding, the monitor-
ing motor voltages are being evaluated to find evolving unbalances. For this purpose, the voltage unbalance is computed and
monitored.
9.131 (ID 3619) Condition-based Monitoring Status
Location in the menu:
V1.24.5
(Multi-Purpose Control Application in VACON
®
NXP only)
This monitoring value shows the fault status of Condition-based Monitoring.
Table 113: Condition-based Monitoring Status
Bit
Signal
B0
Stator Winding Current Warning S1
B1
Stator Winding Voltage Warning S1
B2
Vibration Warning S1
B3
Load Warning S1
B4
-
B5
Stator Winding Current Warning S2
B6
Stator Winding Voltage Warning S2
B7
Vibration Warning S2
B8
Load Warning S2
B9
-
B10
Stator Winding Current Alarm/Fault
B11
Stator Winding Voltage Alarm/Fault
B12
Vibration Alarm/Fault
B13
Load Alarm/Fault
B14
-
B15
-
9.132 (ID 3620) Current Unbalance Threshold Value
Location in the menu:
V1.24.2.2
(Multi-Purpose Control Application in VACON
®
NXP only)
This monitoring value shows the threshold value after interpolating.
9.133 (ID 3621) Voltage Unbalance Threshold Value
Location in the menu:
V1.24.2.7
(Multi-Purpose Control Application in VACON
®
NXP only)
This monitoring value shows the threshold value after interpolating.
9.134 (ID 3622) Baseline Run Status
Location in the menu:
V1.24.1.1
(Multi-Purpose Control Application in VACON
®
NXP only)
This monitoring value shows the baseline run status.