18.

These models are supplied with a factory pre-set programme which will
be active after a RESET has been performed. The pre- s

e

t

programme is shown in the chart with the Setting Instructions.
The chart also has spaces for users own times and temperatures a s
required by them.

19.

The time and programme memory are maintained by the batteries
which should last more than two years. Every 24 months the batteries
should be renewed.  Internal circuitry retains the time and programme
memory for one minute, long enough for the batteries to be changed.

If the batteries volts drop, before a change is due, a battery symbol will
blink  in  the  display.  When  this  occurs  the  TP75-RF  will  operate
normally for 2 weeks. After the 15th midnight all relays will switch to
OFF,  the  unit  will  shut  down  with  just  the  time  shown.  When  new
batteries are fitted the unit will start to operate normally again.

Advise the User to enter their own times and temperatures in the chart on the
Setting Instructions.

Post-commissioning

Optimum Start Control

If this has been enabled, initially set to the recommended 30 minutes start-
up duration and the event 1 temperature is not achieved by the event 1 time,
then refer to the Setting Instructions and increase the start-up duration one
stage, i.e. to 1 hour.
If the space temperature at the beginning of an Optimum Start sequence is
consistently lower than the programmed event 1 temperature by more that
2°F, then the event 1 temperature may not be achieved by the event 1 time.
In  this  case  the  event  1  time  should  be  brought  forward  sufficiently  to
compensate,  so  that  the  comfort  temperature  is  achieved  when  actually
required.

Intelligent Anticipator

If, when the heating equipment is switched on, the room temperature is 4°F
or more lower than the programmed temperature the electronic anticipation
function measures the rate of rise in the sensed temperature and will switch
the heating plant off before the programmed temperature is reached. The
residual heat in the system after the heating plant has shut down will ensure
that  the  comfort  temperature  is  achieved.  This  will  improve  the  comfort
conditions and minimise fuel consumption.

Commissioning

12.

Lower the front flap and remove the anti-discharge paper strip from
between the batteries and their contacts, and ensure the mains power
to the control circuit is switched on.

13.

Press and release the recessed RESET button to ensure the factory
pre-set programme is active.

14. Once the programming has been completed, communication between

the thermostat and the receiver module has to be established.

a)

SINGLE ZONE SYSTEM WITH RX1 RECEIVER

1 -

Press  and  hold  the  LEARN  button  of  the  TP75-RF  for  at  least  3
seconds. The thermostat will now transmit a continuous signal which
contains its unique identity for a period of 5 minutes.

2 -

Within the 5 minute period go to the RX1 receiver module and
press both "PROG" and "CH1" buttons together and hold for at
least 3 seconds, then release.

During this process the RX1 receiver will have learnt the unique
transmission  code  of  the  thermostat  and  will  in  future  react  to  all
transmissions from that thermostat.

To stop the continuous transmission on the TP75-RF unit press the

s

 button.

b)

TWO ZONE SYSTEM WITH RX2 RECEIVER

1 -

Repeat as above for zone one (CH1).

2 -

Repeat steps one and two above for zone two, remembering to
press "PROG" and "CH2" on the RX2 receiver.

c)

THREE ZONE SYSTEM WITH RX3 RECEIVER

1 -

Repeat as above for zones 1 and 2 (CH1 and CH2).

2 -

Repeat as above for zone 3, remembering to press "PROG" and "CH3"
on the RX3 receiver.

15.

Establish with the customer the requirements for the operating
mode, and adjust as follows:

Clock type - 24 hour or 12 hour with AM/PM indication.

The factory pre-set is 24 hour. To convert to 12 hour, press and
hold down the NEXT and DAY buttons until the display changes,
then release. (Repeat to return to a 24 hour clock.)

Temperature display - °C or °F

The factory pre-set is °C. To convert to display all temperatures i n
°F, press and hold down the DAY and COPY buttons until the
display changes. (Repeat to return to a °C display.)

16.

Check the existing space temperature by pressing and holding
down the two buttons: NEXT and COPY, until the display changes from
time to temperature.

17a. If the set temperature is below the space temperature, use the 

 button to raise the set temperature. The flame symbol will appear in the
display.  Check that the heating plant operates correctly.

17b. If the set temperature is above the space temperature, use the  

button to lower the set temperature below the space temperature. The
flame symbol will disappear. Check that the heating plant does not
operate.