3.2 Legacy - RF Pairing
Use this guide when replacing the RF receiver only,
where existing room thermostat is reused.
If both products are changed follow normal pairing
procedure, see 3.1 RF Pairing, page 5.
1. Ensure the power to RX1-S V2 receiver is switched on
and batteries are inserted into the thermostat.
2. Put the thermostat in pairing mode, see thermostat
installation guide.
3. Press and hold the PROG button on the RX1-S V2 until
the PROG button LED (green) turns on.
4. If pairing is successful RF icon on thermostat will stop
flashing and remain on.
5. If pairing is not successful, try moving thermostat to
alternative position and retry.
4. Thermostat Error Codes
Display Description
E1
Sensor Failure
EE
EEPROM Failure
Lo
Measured temperature below 0 °C
Hi
Measure temperature above 50 °C
E3
RF Pairing Failed
E4
RF Signal Lost
E5
RF Hardware Failure
E6
Real Time Clock Failure(TP5001RF Only)