![Danfoss RET2001RF Installation Manual Download Page 9](http://html1.mh-extra.com/html/danfoss/ret2001rf/ret2001rf_installation-manual_3840731009.webp)
Danfoss Climate Solutions AN30483490055001-000103
9
Specifications
RET2001RF /
TP5001RF
RX1-S V2
Battery life
2 years
-
Switch rating
-
3A (1) at
250 Vac
Switch type
-
1x SPDT Type
1 B
Terminals
1 to 2.5 mm2 wires
IP rating
IP30 (installed)
Load compensation
control
Yes
-
On/off control
Yes
-
ErP class
Class IV, ef-
ficiency gain
2 %
-
Construction
EN60730-2-9
EN60730-1
Pollution degree rating
Degree 2
Rated impulse voltage
-
4 kV
Ball pressure test
75 °C
Dimensions
H86 x W86 x
D30
H84 x W84 x
D30
Software classification
A
Operating Frequency
433.100-434.750 MHz
Maximum radio-
frequency power
transmitted
10 dBm
Running and setting
accuracy (for thermostats
with build in timer)
Setting resolution 1 minute.
Ac/- 1 minute per
month.