background image

REP24

24V electronic dial setting thermostat 

with proportional output 

and manual heat cool selection

Installation and Instructions

Summary of Contents for REP24

Page 1: ...REP24 24V electronic dial setting thermostat with proportional output and manual heat cool selection Installation and Instructions ...

Page 2: ...n 3 9 Specification 3 Mounting 4 5 Wiring 6 DIL switch settings 7 Mounting 8 Locking Limiting 9 User Instructions 10 12 Setting the temperature 10 Frost Protection 10 Standby Mode 10 Understanding your thermostat 11 Index ...

Page 3: ...dc Control Method P I Proportional Band 2 K Temperature range 10 30 C Maximum ambient temperature 45 C Control pollution Degree 2 Design standard EN 60730 2 9 Rated impulse voltage 2 5kV Ball hardness test 75 C Dimensions mm 85 wide x 86 high x 42 deep Installation Instructions ...

Page 4: ...4 Mounting Mounting ...

Page 5: ...5 Fix at a height of 1 5m approx from the floor away from draughts or heat sources such as vents heating elements or direct sunlight Mounting Mounting ...

Page 6: ...6 Wiring 1 B A 2 3 4 24 Vac 0V 24V 0V V out output 0 10V ELECTRONICS Wiring ...

Page 7: ...perature is below the setpoint Frost protection mode is available see page 10 COOL proportional output will activate if temperature is above the setpoint Frost protection not available in cooling mode MOT Motorised valve actuator selection WAX Wax valve actuator selection MOT WAX Heat Cool DIL switch settings Sw On ...

Page 8: ...8 Mounting Mounting ...

Page 9: ...ing the thermostat at a temperature which cannot be altered by the user Limiting allowing the user to alter the temperature within a predefined range which is less than the full range of the product i e between 18 22 Locking Limiting ...

Page 10: ...the room drops below 8 C then the output will activate When frost protection is activated the right LED will turn orange Standby Mode In cooling mode the standard frost protection is not available instead there is standby mode When the dial is turned past 10 C the unit enters standby mode and cooling will be inactive until dial is turned up past 10 C Display Setting the temperature User Instructio...

Page 11: ...ion activated Green LED thermostat power on Understanding your thermostat R If the left LED is green the thermostat has power R If the right LED is red the heating function is in operation R If the right LED is green the cooling function is in operation R If the right LED is orange the frost protection is switched on ...

Page 12: ...12 Part No 25283v01 07 08 Danfoss Randall Ltd Ampthill Road Bedford MK42 9ER Tel 01234 364621 Fax 01234 219705 www danfoss com BusinessAreas Heating 2004 108 EC 2006 95 EC ...

Reviews: