background image

Proportional Valve Group

 

PVG 128/256

© Danfoss A/S, 2017-03  

 

AN00000355xx-04

 • Rev 0101 • March 2017 

PVE kontrol specifikationer

PVE control specifications

PVE Steuerungsspezifikationen

PVE spécifications de contrôle

PVE driftsbetingelser

PVE operating conditions

PVE Betriebsbedingungen

PVE conditions de 

fonctionnement

PVEO  Control Specification

Supply Voltage (U

DC

)

Rated

12 V

DC

24 V

DC

Range

11 

→ 

15 V

DC

22 

→ 

30 V

DC

Max. ripple

5 %

5 %

Control Specification

PVEH/H-FLA

PVEH-U

Supply Voltage (U

DC

)

Rated / Range

11 

→ 

32 V

DC

11 

→ 

32 V

DC

Max. ripple

5 %

5 %

Signal Voltage (U

S

)

Neutral

U

S

 = 0.5 • U

DC

U

S

 = 5 V

Q: P 

 A

U

S

 = (0.5 

 0.25) • U

DC

U

S

 = 5 V 

 2.5 V

Q: P 

 B

U

S

 = (0.5 

 0.75) • U

DC

U

S

 = 5 V 

 7.5 V

Signal Voltage PWM (U

S

)

Neutral

U

S

 = 50% DUT

Q: P 

 A

U

S

 = 50% 

 25% DUT

Q: P 

 B

U

S

 = 50% 

 75% DUT

PWM Frequency (US)

Recommended

> 1000 Hz

Input Impedance

Rated

12 kΩ

Input Capacitance

Rated

100 nF

PVEO, PVEH/H-U/H-FLA Operating Conditions

Pilot Pressure

Nominal

13.5 bar [196 psi]

Minimum

10.0 bar [145 psi]

Maximum

15.0 bar [220 psi]

Storage Temp.

Ambient

-50°C 

 90°C [-58°F 

 194°F]

Operating Temp.

Ambient

-40°C 

 90°C [-40°F 

 194°F]

Oil Viscosity

Operating range

12 

 75 cSt [65 

 347 SUS]

Minimum

4 cSt [39 SUS]

Maximum

460 cSt [2128 SUS]

Oil Cleanliness

Maximum

18/16/13 (acc. to ISO 4406)

PVE stik varianter

PVE connector variants

PVE Stecker varianten

PVE variantes de connecteur

1x4 DEUTSCH

1x6 DEUTSCH

1x4 DIN

1

2

3

4

5

6

1

2

3

4

1

2

3

4

Pin

Pin 1

Pin 2

Pin 3

Pin 4

Pin 5

Pin 6

PVEO

1x4 DEUTSCH

U

DC_A

GND

GND

U

DC_B

1x4 DIN

U

DC_A

U

DC_B

GND

PVEH

PVEH-U

1x4 DEUTSCH

U

S

Error

GND

U

DC

1x4 DIN

U

DC

U

S

Error

GND

PVEH-FLA

1x6 DEUTSCH

U

S

Error

Float

GND

U

DC

Summary of Contents for PVG 128

Page 1: ... Nummer Woche und Jahr der Montage und Seriennummer PVP Druckeinstellung D Die Materialnummer ist eingraviert auf dem PVPV PVB und PVSI C PVG numéro semaine et année de montage et numéro sériel PVP réglage de pression D Référence gravée sur les PVPV PVB et PVSI C PVM PVPV D PVB128 PVB256 xxxxxxxx xxxxxxxx xxxx PVM xxxxxx PVSI Flow P A PVMD PVH PVHC PVEO PVEH PVEH U PVEH FLA P006 089 Oliestrømmens ...

Page 2: ...07 24 67 Plads til demontage Room for dismantling Platz für Demontage Espace pour démontage P006 092 L PVP PVGI Max 60 N m 530 lbf in 120 4 7 345 13 6 4 x M12x18 4 x 7 16 14UNC x 0 7 345 13 6 120 4 7 PVB 256 1 2 3 4 5 6 7 L mm 118 5 204 5 290 5 376 5 462 5 548 5 634 5 L in 4 67 8 05 11 44 14 82 18 21 21 59 24 98 Indstilling af maks oliestrøm Setting of max flow Einstellung des max Ölstroms Réglage...

Page 3: ... valve LSA B Product Rated pressure PVG 128 with PVSI 350 bar 5076 psi PVG 256 w PVSI 350 bar 5076 psi PVG Udluftning Hvis gruppen er monteret vertikalt anbefales det at udlufte ved justerskruer Pos A PVG Bleeding If the group is installed vertically it is recommended to bleed it at the adjusting screws Pos A PVG Entlüftung Wenn die Gruppe vertikal montiert ist empfehlen wir an den Justierschraube...

Page 4: ...hørende komponenter ses som en samlet enhed og må derfor ikke adskilles For safety reasons the PVE actuator and interface components must be considered as one unit Do not try to disassemble under any circumstances Aus Sicherheitsgründen müssen der PVE Aktuator und die Verbindungs Komponenten als eine Einheit betrachtet werden Unter keinen Umständen versuchen zu demontieren Pour des raisons de sécu...

Page 5: ...l US 50 DUT Q P A US 50 25 DUT Q P B US 50 75 DUT PWM Frequency US Recommended 1000 Hz Input Impedance Rated 12 kΩ Input Capacitance Rated 100 nF PVEO PVEH H U H FLA Operating Conditions Pilot Pressure Nominal 13 5 bar 196 psi Minimum 10 0 bar 145 psi Maximum 15 0 bar 220 psi Storage Temp Ambient 50 C 90 C 58 F 194 F Operating Temp Ambient 40 C 90 C 40 F 194 F Oil Viscosity Operating range 12 75 c...

Page 6: ...or making the final selection of the products and assuring that all performance safety and warning requirements of the application are met The process of choosing the control system and safety level could e g be governed by EN 954 1 Safety related parts of control system See also Technical information for PVE series 7 WWarnung Alle Fabrikate und Typen von Wegeventilen einschließlich Proportionalve...

Reviews: